Loading...
B. SCE Reliability ReportCirc uit Re liability Re view Grand Te rrace 2021 •Southern California Edison (SCE) is an Edison International company •One of the nation’s largestelectricutilities •More than 130 year s of histor y •Headquar tered in Rosemead, California •Regulated by the California Public Utilities Commission (CPUC)and the Federal Energy Regulator y Commission (FERC) •50,000 square miles of SCE ser vice area across Central, Coastal,and Southern California •15 million residents through 5 million customer accounts •445 communities and 13 Native American tribes Who We Are 2 Our Grid To deliver safe,reliable,and affordable power, we monitor and maintain a vast electricity system 730,000 Transformers 119,000 Miles of Transmission and Distribution Lines 4,600 Circuits 1.4 Million Poles 50,000 Square Miles 3 Strengthening and Modernizing the Grid •Infrastructure reliability –updating underground cables,poles,switches,and transformers •Wildfire mitigation –hardening infrastructure, bolstering situational awareness capabilities, and enhancing operational practices •Transmission –connecting renewables,installing new substations,and updating lines •Grid readiness –updating the grid for impacts from new technologies •Long-term energy policy –suppor ting energy storage,electric vehicles,and renewables SCE plans to spend more than $5B eachyeartomaintain, improve, and hardenits infrastructure SCE’s investments suppor t safe,reliable,affordable,and clean energy for our customers 2020 Capital Investments 235 miles of underground cable replaced 97 miles of overhead conductorreplacedforpublicsafety 11.1k distribution poles replaced 3.6k transmission poles replaced 79 underground structurereplacements 4 Protecting Public Safety:Wildfire Mitigation Activities 2020 Year-End Progress Repor t –Data as of 12/31/20 5 Protecting Public Safety:Public Safety Power Shutoffs •To reduce the threat of wildfires,SCEimplementsPublic Safety Power Shutoffs (PSPS)to temporarily shut off power to somecustomersinareaswithahighriskforwildfirestopreventtheelectricsystemfrombecomingthesourceofignition •PSPS is used as a measure of last resor t toprotectpublicsafetyunderdangerousfireweatherconditions, including high winds, low humidity,and dr y vegetation •Multiple methods are used to notif y people inaffectedareasbefore,during and af ter a PSPSevent •SCE provides resources to suppor t customers during PSPS and offers several programs andrebatestohelpcustomersbepreparedand more resilient during emergencies •SCE is working to reduce the impact of PSPSand is continuing to strengthen the electric grid to become more resilient in the face ofextremeweatherevents 6 Pathway 2045:Key steps California must take to reach carbon neutrality Creating a Clean Energy Future 100%of grid sales with carbon-free electricity 80 GW of utility-scale clean generation 30 GW of utility-scaleenergy storage 7 70%of all buildings will use efficient electric space and water heating 90%fewer GHG emissions from all-electric homes 26 million electric vehicles Over 1 million electrified medium and heavy duty vehicles 50%reduction in natural gas consumption 40%of the remaining natural gas is biomethane and hydrogen Reliability Over view What is Reliability? •In simplest terms: Having dependable electricity when you need it. •Outages: •Maintenance outages (aka planned outages) •Repair outages (aka unplanned outages) •Sustained Outage =An outage lasting > 5minutes •Momentar y Outage = An outage lasting ≤5minutes •Public Safety Power Shutoff (PSPS) Major Event Day (MED):A day in which the daily system SAIDI exceeds a threshold value.For the purposes of calculating daily system SAIDI, any interruption that spans multiple calendar days is accrued to the day on which the interruption began.Statisticall y,days having a daily system SAIDI greater than a threshold value are days on which the energy delivery system experienced stresses beyond th at normally expected (such as severe weather). Public Safety Power Shutoff (PSPS) :An operational protocol that SCE implements under extreme weather conditions in order to minimize the threat of wildfires and keep communities safe from potentially dangerous situations. These types of sustained outages are temporary and usually involve situations where high fire areas are experiencing adverse weather or public safety is at risk. 9 How Do We Measure Reliability? 10 11 Over view of Grand Terrace There are 5 circuits that ser ve Grand Terr ace 1 Gran d Total 8,166 Note:The number of customers listed represents the total number of customers on each circuit (not the local jurisdiction). Circuit Type Customers Circuit Type Customers Circuit Type Customers Circuit Type Customers COOLEY(12KV)1,615 DOMIC(12KV)1,274 GLOBE MILLS(12KV)889 PRESTON(12KV)2,445 URBITA(12KV)1,943 SCE SYST E MWID E **Da ta is as o f 03/16/2021,data can b e s lig htly d iffer ent d ue to o utage data va lidatio n p r o cess Gra nd Terra ce Re lia bility His tor y of Circuits Ser vin g G r a n d Te rra c e (No E xc l usi o ns) **“Exclusions”ar e days which utilities ar e allo wed to r emo ve fro m their metr ics because the o utages o n tho se days wer e caused b y a cts of nature. 437.0 80.8 66.1 422.0 139.7 136.8 178.0 201.3 15 0.0 10 0.0 50 .0 0.0 25 0.0 50 0.0 45 0.0 40 0.0 35 0.0 20 17 20 18 2019 20 20 SA ID I m inutes o f susta ine d interrup tio ns) 2.1 1.3 1.0 1.9 1.2 0.9 1.0 1.1 0.0 0.5 1.0 1.5 2.0 2.5 SA IF I(avera g e freque ncy o f sustained inte rrup tio ns) 2.4 12 2.0 1.0 1.61.8 1.4 1.4 1.4 1.0 0.5 0.0 1.5 2.0 2.5 3.0 M A IFI(avera g e frequency ofmomentary interrup ti o ns) S A ID I =the cu m u lativ e a m o unt of tim e the a v er a ge custom er is in terru pted by “s ustain ed”ou tages each y ea r . C a use s o f R e pai r O u tag e s i n G r a n d Te rra ce 2020 W eath er /F ir e /Ear th qu a ke36.0 % 13 O ther 33.0 % E qu ipm en t Failur e 30.3 % O per atio n 0 .5 % 3rd Par ty 0 .1 % Vegeta tio n /Anim al 0 .0 %P S PS 0 .0 % C o n tr i b u ti o n s t o S A I D I by O u t a g e Cause▪Equipme nt Failur e e.g .,in -s ervice f ailu r e of tr an s former,s witch,or conductor s ▪Ve g etat ion/A nim al e.g ., tr ee br a nch,r oden t, o r b ir d c aus ing a s hor t cir cuit b etw een conductor s ▪O t he r e.g.,patr o lled but no c aus e f ound ▪O pe r at ions e.g.,ur gent m a in ten ance w /o 3 -day notice ▪3 rd Part y e.g.,b alloon, c ar hit pole, d ig -in ▪PSPS e.g.,P ublic S af ety P o w er S huto ff S AIFI =the num ber of tim es the average custom er is interrupted by “sustained”outages each year C o n tr ib u tio n s to SA I FI by O u tag e Cau s e Other 37.2% W eather /Fire /Earth quake10.0 % O per ation1.0 %3 r d Par ty 0 .1 %PS PS Equipm ent Failure 0 .0 %51.7 %Vegetation /Anim al 0.0% Ca use s of Re pa ir Outag e s in Gra nd Te rra ce 2020 C o n tr ib u tio n s to SA I FI by O u tag e Cau s e 14 ▪Equipment Failure e.g.,in-s e rvice failure of trans former,s witch,or conductors ▪Vegetation/A nimal e.g.,tree branch,rodent,or bird caus ing a short circuit betw een conductors ▪Ot he r e.g.,patrolled but no caus e found ▪Operations e.g., urgent maintenance w /o 3 -day notice ▪3rd Party e.g.,balloon,car hit pole,dig-in ▪PSPS e.g.,Public Safety Pow er Shutoff Equipm ent Failure 51.7 % Other 37.2 % W eather /Fire /Ear thquake10.0 %O per ation 1 .0 % 3 rd Party 0 .1 % Vegetation /Anim al 0 .0 %P S PS 0 .0 % 15 16 Back-up Slides 17 Reliability Histories of Circuits Serving Grand Terrace Updated through Dec 2020 18 AverageRe liabilityof5CircuitsServing Grand Terrace Notes: No outages are excluded from the metrics. Outage Causes: Other:e.g.,patrolled but no cause could be found Operations:e.g.,urgent maintenance w/o 3-day notice to customers 3rd Party:e.g.,balloons,car hit pole,dig-in Vegetation/Animal:e.g.,tree branch,rodent,or bird causing short circuit across conductors PSPS:e.g.,Public Safety Power Shutoff SAIDI (minutes)= the cumulative amount of time the average customer is interrupted by “sustained”(longer than 5 minutes)ou tages. SAIFI (interruptions) = the number of times the average customer is interrupted by “sustained”outages. MAIFI (interruptions)=the number of times the average customer is interrupted by “momentary "(lasting 5 minutes or less)outages. 2017 2018 2019 1st Qtr2020 2ndQtr202 0 3rd Qtr2020 4thQtr202 0 2020 SAIDI SAIFI MAIFI SAIDI SAIFI MAIFI SAIDI SAIFI MAIFI SAIDI SAIFI MAIFI SAIDI SAIFI MAIFI SAIDI SAIFI MAIFI SAIDI SAIFI MAIFI SAIDI SAIFI MAIFI5CircuitsServingGrand Terrace --Total Customers:8,166 437.0 2.1 2.4 80.8 1.3 2.0 66.1 1.0 1.0 1.7 0.0 0.3 24.1 0.1 0.3 162.3 1.0 0.7 234.0 0.7 0.4 422.0 1.9 1.6 3rd Party 6%17%33%22%20%40%16%33%29%15%4%-1%1%48%--23%---0%0%18%Equipment Failure 11%19%7%63%63%15%61%52%50%12%18%-99%99%52%42%67%23%16%24%14%30%52%22%Operation 15%27%14%4%15%1%3%1%21%7%21%-0%0%-1%1%-0%0%11%1%1%3% Other --23%10%2%22%19%12%---100%---58%32%54%20%51%75%33%37%58%Vegetation/Animal ---0%0%21%------------------ Weather/Fire/Earthquake 69%37%22%---1%2%-67%57%-------65%25%-36%10%- PSPS ------------------------ SCE SYSTEMWIDE 139.7 1.2 1.8 136.8 0.9 1.4 178.0 1.0 1.4 17.1 0.2 0.3 17.2 0.2 0.4 71.4 0.3 0.4 95.5 0.4 0.4 201.3 1.1 1.4 CircuitHistory1 19 ReliabilityHistories for Individual CircuitsServingGrand Terrace -1of 2 2017 2018 2019 1st Qtr2020 2nd Qtr 2020 3rd Qtr2020 4th Qtr202 0 2020 SAIDI SAIFI MAIFI SAIDI SAIFI MAIFI SAIDI SAIFI MAIFI SAIDI SAIFI MAIFI SAIDI SAIFI MAIFI SAIDI SAIFI MAIFI SAIDI SAIFI MAIFI SAIDI SAIFI MAIFI COOLEY(12KV)-Customers:1,615 684.3 1.8 1.7 ---78.8 1.9 2.0 ------0.8 0.0 -188.7 0.2 -189.6 0.2 - 3rd Party --55%--------------------- Equipment Failure 8%50%45%---94%95%50%------100%100%----0%0%- Operation ------4%0%50%--------------- Other ------------------100%100%-100%100%- Vegetation/Animal ------------------------ Weather/Fire/Earthquake 92%50%----3%4%---------------- PSPS ------------------------ DOMIC(12KV)-Customers:1,274 313.5 3.9 4.4 88.0 2.2 4.2 69.3 2.1 1.8 9.1 0.0 -0.3 0.0 0.8 84.1 1.1 2.1 82.9 0.0 2.0 176.5 1.1 4.9 3rd Party --37%--23%83%98%100%18%7%-100%100%100%--50%---1%0%38%Equipment Failure 32%21%-57%52%26%15%2%-------98%98%50%---47%91%21%Operation 27%53%-7%43%-2%0%-3%2%----2%2%-6%33%-4%3%- Other --41%37%5%26%1%0%------------100%--41%Vegetation/Animal -----26%------------------ Weather/Fire/Earthquake 42%26%22%------79%91%-------94%67%-48%5%- PSPS ------------------------ GLOBE MILLS(12KV)-Customers:889 128.0 1.8 1.0 35.9 1.0 2.0 111.6 1.1 ---2.5 ---15.2 1.0 -334.4 1.6 1.0 349.6 2.6 3.4 3rd Party ---94%99%------------------- Equipment Failure 48%7%-5%1%-1%5%-------100%100%-100%100%57%100%100%16%Operation 29%38%----3%0%------------43%--12%Other ------96%95%---100%-----------72%Vegetation/Animal ---2%1%100%------------------ Weather/Fire/Earthquake 23%55%100%--------------------- 20 ReliabilityHistories for Individual CircuitsServingGrand Terrace -2of 2 2017 2018 2019 1st Qtr2020 2nd Qtr 2020 3rd Qtr2020 4th Qtr2020 2020 SAIDI SAIFI MAIFI SAIDI SAIFI MAIFI SAIDI SAIFI MAIFI SAIDI SAIFI MAIFI SAIDI SAIFI MAIFI SAIDI SAIFI MAIFI SAIDI SAIFI MAIFI SAIDI SAIFI MAIFI URBITA(12KV)-Customers:1,943 26.0 0.0 2.1 127.2 1.7 2.5 82.4 0.6 0.5 ---98.9 0.5 0.6 2.5 0.0 -583.5 0.7 -684.9 1.2 0.6 3rd Party ---1%1%81%6%6%---------------- Equipment Failure 99%97%-93%94%19%88%87%100%---100%100%100%36%33%-0%0%-15%39%100%Operation --48%6%5%-4%5%-------64%67%----0%1%- Other ------2%2%---------------- Vegetation/Animal ------------------------ Weather/Fire/Earthquake 1%3%52%---------------100%100%-85%60%- PSPS ------------------------ ------------------------- ------------------------- ------------------------- ------------------------- ------------------------- ------------------------- ------------------------- ------------------------- ------------------------- ------------------------- ------------------------- ------------------------- ------------------------- ------------------------- ------------------------- ------------------------- ------------------------- ------------------------- ------------------------- ------------------------- ------------------------- ------------------------- ------------------------- -------------------------