Loading...
348ORDINANCE NO 348 AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF GRAND TERRACE, STATE OF CALIFORNIA, FINDING ZONING CODE AMENDMENT 22-03 IS EXEMPT FROM CEQA PURSUANT TO SECTION 15061(B)(3) AND AMENDING TITLE 18 OF THE GRAND TERRACE MUNICIPAL CODE BY ADDING CHAPTER 1864 ESTABLISHING OBJECTIVE DESIGN STANDARD REQUIREMENTS WHEREAS, the City of Grand Terrace ("City") adopted a zoning code, which has been amended from time to time, and WHEREAS, pursuant to Sections 65800 and 65850 of the California Government Code, the City may adopt ordinances to regulate the use of buildings in compliance with the California Government Code, and WHEREAS, the proposed Zone Code Amendment 22-03 to the Municipal Code is consistent with the goals and policies of the City of Grand Terrace General Plan, and WHEREAS, this Ordinance proposes to amend the Municipal Code, Title 18 (Zoning), Chapter 18 64 establishing Objective Design Standard requirements as provided in Zone Code Amendment 22-03, which is attached hereto and incorporated herein by this reference as Exhibit A, and WHEREAS, the City Council has determined that Objective Design Standards meet the intent of Assembly Bill 35 to streamline the review process for multi -family residential projects while maintaining high development standards, and WHEREAS, I Municipal Code, the to the Zoning Code, WHEREAS, Zc Environmental Quality / is covered by the gener for causing a significant there is no possibility t environment, the activit Code to include obje environmental impacts WHEREAS, on introducing the propos to staff, and cant to Chapter 18 90 (Amendments) of the City of Grand Terrace Council shall hold a public hearing on any proposed amendment ling Code Amendment 22-03 is exempt from California ;t (CEQA) pursuant to Section 15061(b)(3) which states the activity I rule that CEQA applies only to projects [that] have the potential affect on the environment Where it can be seen with certainty that at the activity in question may have a significant effect on the is not subject to CEQA Amending the Grand Terrace Municipal .tive design standards would not result in any significant ue to the narrow scope of the project, and ay 19, 2022, the Planning Commission received a presentation Objective Design Standard requirements and provided comments Ord No 348 1 Page 1 of 4 March 28, 2023 WHEREAS, on June 16, 2022, the Grand Terrace City Council and Planning Commission/Site and Architectural Review Board ("Planning Commission") conducted a joint workshop discussing Objective Design Standard requirements providing comments to staff, and WHEREAS, on January 19, 2023, the Grand Terrace Planning Commission conducted a duly noticed public hearing at a regular meeting of the Planning Commission on Zoning Code Amendment 22-03 at the Grand Terrace City Hall Council Chamber located at 22795 Barton Road, Grand Terrace, California and concluded the hearing by adopting a Resolution recommending 5-0 that the City Council determine that this Ordinance is exempt from CEQA pursuant to Section 15061(b)(3) and approve this Ordinance establishing Objective Design Standard requirements, and WHEREAS, on February 14, 2023, the Grand Terrace City Council conducted a duly noticed public hearing on Zoning Code Amendment 22-03 at the Grand Terrace Council Chamber located at 22795 Barton Road, Grand Terrace, California 92313 and voted unanimously 4-0 to continue the hearing and directed staff to schedule a Community Workshop, and WHEREAS, on March 14, 2023, a Community Workshop was held from 4 00 p m to 6 00 p m at the Council Chamber located at 22795 Barton Road, Grand Terrace, California on Zoning Code Amendment 22-03 proposing Objective Design Standards The Objective Design Standards workshop flyer was posted in the city's kiosk, on the city's Website, Facebook, Twitter, and e-mail blast In addition, the Objective Design Standards workshop flyer was printed in the local adjudicated newspaper on March 2, 2023, and March 9, 2023, and WHEREAS, on March 14, 2023, the Grand Terrace City Council conducted a duly noticed public hearing at the regular meeting on Zoning Code Amendment 22-03 at the Grand Terrace City Hall Council Chamber located at 22795 Barton Road, Grand Terrace, California and concluded the hearing and voting unanimously 4-0 to adopt a Resolution on March 14, 2023, and to conduct a second reading on March 28, 2023, and WHEREAS, all legal prerequisites to the adoption of this Ordinance have occurred NOW THEREFORE, THE CITY COUNCIL OF THE CITY GRAND TERRACE DOES ORDAIN AS FOLLOWS SECTION 1 The City Council hereby specifically finds that all the facts set forth in the above Recitals, are true and correct and, further, incorporated such facts herein SECTION 2 Based upon the forgoing and all oral and written testimony by members of the public and City staff (including, but not limited to, staff reports and attachments) made at the public hearing, the City Council hereby finds that the Project is not subject to environmental review pursuant to Section 15061(b)(3) of Title 14 of the California Code of Ord No 348 Page 2 of 4 March 28, 2023 Regulations because the revisions are regulatory in nature and will not in themselves create impacts to the environment SECTION 3 Based upon the forgoing and all oral and written testimony by members of the public and City staff (including, but not limited to, staff reports and attachments) made at the public hearing, the City Council specifically finds as follows 1 Zoning Code Amendment 22-03 will not be detrimental to the health, safety, morals, comfort, or general welfare of the persons residing or working within the City because these amendments establish "Objective Design Standard" requirements that will support State requirements to provide ministerial review on multi -family projects and mixed -use development while preserving the architectural standards to create and promote visual character of the community and protecting the quality of life of residents and visitors 2 Zoning Code Amendment 22-03 is consistent with the General Plan and the Municipal Code because these amendments establish "Objective Design Standard" requirements that support the goals and policies of the General Plan programs and policies that will preserve and enhance the quality and character of the city, encourage street oriented mixed -use and multi -family residential projects while maintaining the highest standards to provide development that will enhance the surrounding development 3 Zoning Code Amendment 22-03 will not be injurious to property or improvements in the neighborhood or within the city The establishment of "Objective Design Standards" create a set of requirements that maintain high quality of design and construction for multi -family and mixed -use development The Objective Design Standard requirements will allow the construction of high -density development that will revitalize the city's image and enhance the visual character of the community as well as curb the negative impacts of multi -family and mixed -use developments in general SECTION 4 Based upon the forgoing and all oral and written testimony by members of the public and City staff (including, but not limited to, staff reports and attachments) made at the public hearing, the City Council finds this Ordinance, adopting Objective Design Standards 22-03, is exempt from CEQA pursuant to section 15061(b)(3) SECTION 5 Based upon the forgoing and all oral and written testimony by members of the public and City staff (including, but not limited to, staff reports and attachments) made at the public hearing, the City Council hereby amends Title 18 (Zoning) of the Grand Terrace Municipal Code as provided in Exhibit A, attached hereto and incorporated herein by reference SECTION 6 Inconsistencies Any provision of the Grand Terrace Municipal Code or appendices thereto inconsistent with the provisions of this Ordinance, to the extent of such Ord No 348 Page 3 of 4 March 28, 2023 inconsistencies and no further, is hereby repealed or modified to that extent necessary to affect the provisions of this Ordinance SECTION 7 Severability Should any provision of this Ordinance, or its application to any person or circumstance, be determined by a court of competent jurisdiction to be unlawful, unenforceable or otherwise void, that determination shall have no effect on any other provision of this Ordinance or the application of this Ordinance to any other person or circumstance and, to that end, the provisions hereof are severable The City Council of the City of Grand Terrace declares that it would have adopted all the provisions of this Ordinance that remain valid if any provisions of this Ordinance are declared invalid SECTION 8 Effective Date This Ordinance shall become effective thirty (30) days from and after its adoption SECTION 9 First read at a regular meeting of the City Council held on the 14th day of March 2023, and adopted the Ordinance after the second reading at a regular meeting field on the 28th day of March 2023 J SECTION 10 Certification The Mayor shall sign, and the City Clerk shall certify to the passage and adoption of this Ordinance and shall cause the same to be published and posted pursuant to the provisions of law in that regard and this Ordinance shall take effect 30 days after its final passage PASSED, APPROVED AND ADOPTED by the City Council of the City of Grand Terrace at a regular meeting held on the 28th day of March 2023 Eil ussey, Mayor ATTEST e ra Thomas City Clerk APPROVED AS TO FORM Adrian R Guerra City Attorney Ord No 348 Page 4 of 4 March 28, 2023 Exhibit A Chapter 18 64 OBJECTIVE DESIGN STANDARDS Sections 18 64 010 Purpose, Intent and Applicability 18 64 020 Other Standards and Requirements 18 64 030 Definitions 18 64 040 Sustainable Design 18 64 050 Building Design 18 64 060 Site Design 18 64 070 Additional Standards 18 64 080 Additional Mixed Use Standards 18 64 090 Permits and Approvals 18 64 010 Purpose, Intent and Applicability This chapter is intended to implement the provisions consistent with Senate Bill No 35 and Senate Bill 330, Government Code Sections 65400 A Purpose The purpose of this Chapter is to establish design standards that are objective for multifamily residential development and mixed -use development with a residential component to ensure that such development is attractively designed, maintains positive aesthetic characteristics, and to provide property owners and developers with predictable design approval standards for such development The standards established in this Chapter are supplemental to the development standards applicable to multifamily residential development and mixed -use development as established within the Municipal Code for each zoning district allowing such use This Chapter also establishes conditions and procedures for processing streamlined housing projects consistent with Government Code Section 65913 4 B Intent It is the intent of this Chapter to provide design standards that are objective while also ensuring that the City's requirements for quality design of multifamily residential development and mixed -use development with a residential component are satisfied These design expectations are to be applied uniformly, and without discretion, to enhance the built environment within the City for both affordable and market -rate multifamily residential development C Applicability The provisions of this Chapter apply to all multifamily residential developments and mixed -use development with a residential component as defined herem Regarding the permitting process in particular, any application that complies with all provisions of this Chapter and regulations of the applicable zoning district 1 shall be eligible for a ministerial review process, as set forth in Section 18 64 080 (Permits and Approval) When an applicant elects to deviate from the objective design standards set forth in this Chapter, a ministerial review process shall not apply and the development application shall be subject to any required discretionary application types, review and approvals as set forth in Chapter 18 63 (Site and Architectural Review) 18 64 020 Other Standards and Requirements A Zoning and Development Standards A multifamily residential development or mixed -use development with a residential component that is designed in conformance with this Chapter shall also comply with all development standards and regulations of the designated zoning district and other applicable provisions of Title 18 (Zoning) B Subdivision Regulations A multifamily residential development or mixed -use development with a residential component that is designed in conformance with this Chapter that requires the approval of a subdivision action in order to establish a legal building site for such development, shall comply with all applicable requirements of Title 17 (Subdivisions) C Building/Fire Codes A multifamily residential development or mixed -use development project with a residential component that is designed in conformance with this Chapter shall also comply with all applicable regulations of Title 15 (Buildings and Construction), including but not limited to plan check review, permit issuance and applicable fees Projects must comply with San Bernardino County Fire submittal and review requirements D California Environmental Quality Act (CEQA) A multifamily residential development or mixed -use development project with a residential component that is designed in conformance with this Chapter, qualifying for a ministerial review process, shall be considered exempt from CEQA pursuant to Government Code Section 65913 4 This exemption does not preclude a determination by the City that certain technical reports (e g , stormwater quality management plan, water and sewer studies, traffic studies, noise studies, parking studies, biological survey, historical survey) are required as part of the standard submittal checklist established by the Director, or as required through the imposition of standard conditions of approval Any required technical reports shall conform to City requirements established for such reports Projects that do not qualify for a ministerial review process shall be reviewed in compliance with the applicable CEQA guidelines for discretionary application types 18 64 030 Definitions For purpose of this chapter, the following terms shall be defined as follows A "Multifamily Residential Development" means a building(s) with two or more 2 attached residential units It also includes a mixed -use development with a residential use as defined herein This term does not apply to accessory dwelling units generally unless the application is for new construction of a single-family home with an attached accessory dwelling unit B "Mixed -Use Development" means a building(s) and site where at least two-thirds (2/3) of the square footage of the building(s) shall be designated for residential use The two-thirds (2/3) calculation is based upon the ratio of gross square floor area (square feet) of residential units and related residential facilities to gross building(s) floor area (square feet) for the nonresidential use, such as commercial Buildings that include both residential and nonresidential uses shall be credited proportionate to the intended use The calculations of building(s) square footage shall not include non - conditioned building floor area or below -grade floor area, such as basements, or underground parking garages C "Ministerial Review Process" means a process for development approval involving little or no personal judgment by the City as to the wisdom or manner of carrying out the project The ministerial review process simply ensures that the proposed development meets all the requirements of this Chapter D "Objective Design Standards" are defined in Government Code Sections 65913 4 and 66300 (a)(7) to mean that no personal or subjective judgment is used by the City The standards are uniformly verifiable by reference to an external and uniform benchmark or criterion available and knowable by both the development applicant/proponent of the project and City prior to submittal of a development application 18 64 040 Sustainable Design A LEED Platinum Requirement For the purposes of this Chapter, all multifamily residential buildings and sites and mixed -use buildings and sites with a residential use shall demonstrate that the application qualifies for the "Platinum Level Certification," or an equivalent standard as defined by the Leadership in Energy and Environmental Design (LEED) of the United States Green Building Council Plans and/or supplemental specifications shall be provided at the time an application is submitted for preliminary or formal review as required by City application forms/checklists as established by the Director B Water Efficient Landscape Requirement For the purposes of this Chapter, all multifamily residential development and mixed -use development with a residential use shall demonstrate that the application is in compliance with all applicable requirements by the Riverside Highland Water Company and compliance with the City's Water Efficient Landscape regulations in Chapter 15 56 The landscaping application shall demonstrate conformance with the latest Model Water Efficient Landscape Ordinance (MWELO) guidelines by the California Department of Water Resources Plans and/or supplemental specifications shall be provided at the time an 3 application is submitted for preliminary or formal review as required by City application forms/ checklists established by the Director 18 64 050 Building Design Unless otherwise noted, development shall comply with the Municipal Code design development standard requirements of the underlining zoned district in which they are located, including but not limited to front setback requirements, distance between buildings, required height, and lot coverage A Residential Entries The following standards apply to first floor street or publicly accessible common open space -facing fagades of residential or mixed -use buildings The primary orientation of a building or unit entrance in multifamily residential site shall be designed in accordance with the following standards Street -oriented Entries Buildings fronting a public street shall have a primary residential door entrance oriented to the public street or oriented to within 45 degrees of the line parallel to a public street intersection as illustrated in Figure 18 64 050A Direct and unobstructed universal access shall be provided between the public sidewalk and the residential primary building entrance Where a site is located on two or more public streets, the primary building first floor residential entry shall be oriented toward the street with the highest roadway classification as defined in the Circulation Element of the Grand Terrace General Plan If a multi- family site fronts two public streets of equal roadway classification, either street frontage may be used to meet the entry standard 2 Individual Residential Unit Entries Multi -family residential buildings with exterior residential unit entries shall front and be setback a mimmum of ten (10) feet from the public sidewalk Entries shall be linked to the public sidewalk with a ten (10) foot minimum width access walkway, ramp, and/or stairs as illustrated in Figure 1864050A 11 Right - of -Way i �I 10' Minimum Depth Fagure 18 64 050 A 10' Minimum Depth Right -of -Way Street © Individual entry - Ten foot minimum front setback ® Street oriented entry - Individual residential unit entries Property Line Common Open Space-onented Entries Multi -family residential building primary entries are permitted to be located at the first floor and directly accessible from publicly accessible common open space paseos, courtyards, plazas, or a street fronting residential setback as illustrated in Figure 18 64 050B Common open space entries shall have direct sightlines and continuous and unobstructed universal access sidewalk routes between the entries and the street public sidewalk 4 Exterior Multiple Unit Entries Residential entrances serving multiple units shall be accessed from a first floor lobby or stairwell that is linked to a public sidewalk, publicly accessible open space, or residential front setback Exterior entrances to individual units on upper floors utilizing an exterior access corridor visible and/or connecting to a public street shall serve a maximum of four units and shall be recessed with a minimum depth of ten (10) feet as illustrated in ,Figure 18 64 050 B 5 V a) ,is ifi Right - of -Way Figure 18 64 050 B Street ® Common open space or setback Exterior multiple unit or individual unit entries Lobby or stairwell upper floor multiple entries l f [ Sidewalk B Modulation and Articulation The massing and articulation of buildings in multifamily residential development shall be designed in accordance with the following standards Setbacks Multifamily units that are anticipated to have impact adjacent development privacy To mitigate the impacts, the following standards shall apply, as illustrated in Figure 18 64 050C a Minimum requirements When a multifamily residential building is constructed adjacent to any parcel that includes an existing structure, a fifteen (15) foot setback is required wherever the multifamily building is located within ten (10) feet of a required side or rear setback The setback shall be for stones that are one (1) story greater than the highest roof line elevation of any existing residential structure C. b Size and location of windows To mitigate privacy impacts, residential units shall reduce the number and locate residential windows to minimize sightlines to existing development All California Building Code egress window requirements for residential occupied units shall be met c Landscape privacy screening When adjacent to existing residential development, a 10- foot landscaped setback shall include vertical evergreen trees, at a minimum height of 20 feet, and maximum spacing of 10 feet on -center at installation All privacy screening trees shall be planted at a nummum of twenty-five (25) percent of full growth maturity All trees shall be provided at a minimum size of 36-mch box Figm a 1S 64 050 C Nem Multi -Family Residential H®Idmg Facade Modulation As illustrated in Figure 18 64 050D, all building facades shall be articulated horizontally a minimum of every fifty (50) feet along all sides, using facade projections, recesses, or step backs of upper floors Facade area used to meet this standard shall be a minimum of five feet in depth and 10 feet in width and shall be articulated vertically a minimum of two-thirds (2/3) of the height of the structure 7 Figure 18 64 050 D OPTION 1 OPTION 2 2�3 (Min) (Min) � s Fifty foot Fifty foot mmunum nununum 0 Projected area - Five foot depth x ten foot width minimum 0 Recessed area - Five foot depth x ten foot width minimum 0 Required facade area - 213 Of total facade area 0 Required facade area - 213 of total facade area 2 Fagade Articulation Articulation of any facade greater than 20 feet in length along any street- facing frontage, or 30 feet along any fagade These facades shall be articulated by incorporating at least three (3) of the following features each of which is illustrated in Figure 18 64 050E a Window and door fenestration All individual or window and door systems shall project a minimum of two (2) inches in depth from the primary wall plane or shall be recessed from the primary wall plane a minimum of three (3) inches, b Recessed ground floor modulation Exterior arcades, porticos or cantilevered ground floor building recesses that provide sheltered walkways, patios, stoops or porches within the building footprint, having a minimum area of fifty (50) square feet, c Horizontal modulation Projected or recessed bay, onel, or alcove of a minimum two (2) foot depth variations from the primary wall plane for 30 percent of building frontage, d Modulated entries A recessed stoop or porch or projected vestibule or foyer unit entry with a mmnmum area of fifty (50) square feet, or e Vertical articulation pilasters which project a minimum of six (6) inches in depth from the primary facade and extend the full height of the building from the first story finished floor elevation to the rooftop eave or top of parapet or cornice line Figui a 18 64 050 E a -Window and door fenestration am us UUU Windows and door et recessed or projected Stfe c - Horizontal modulation b - Recessed ground floor modulation Ground floor recessed 5{xQe'k d - Modulated entries Stoops recessed and vestibules are projected StXe2 e - Vertical articulation pilasters LJ Pilasters project from et primary facade Stye 3 Roofline Articulation All building rooflmes shall be vertically articulated at least every fifty (50) feet, through one of the following techniques as illustrated in Figure 18 64 050F a Option 1- An increase or decrease in height of a minimum four (4) feet, b Option 2- A change in at least one (1) roof pitch or form, or c Option 3- Articulation of the roofline utilizing of one (1) of the following- dormers, gables, varying height cornices, and/or clerestory windows Z F agm-e 18 64 05OF OPTION 1 OPTION 2 OPTION 3 Four foot increase or decrease Roof form change Roofline articulation 0 Street fronting building facade Dormers 4 Horizontal Articulation Buildings three (3) stones or greater in height shall be horizontally articulated a minimum of every one hundred (100) feet along all frontages through the use of either fagade recesses or facade projections Setbacks or projections shall be a minimum of five (5) feet in depth and ten (10) feet in width and shall extend the full height of the building from the first story finished floor elevation to the roof eave or top of parapet or cornice line 5 Vertical Articulation Buildings three stones or greater in height shall vertically differentiate the function and use of the first story from the upper story(s) by providing a facade cladding material change between the first story and upper stones for a minimum of 75 percent of all facades Facades shall incorporate at least two of the following to achieve tlus differentiation as illustrated in Figure 18 64 050G a Recesses or Projections Variation in, the primary facade plane projecting or recessing a minimum of four (4) inch in depth at the vertical transition line between the first story and upper story(s) facade materials b Horizontal Banding Horizontal articulation between the first story and upper story(s) primary facade planes utilizing a twelve (12) inch projecting ornamental or functional water table, belt course, molding or ledge c Masonry Base The first floor primary facade shall consist of a masonry material, including hand laid and mortared field stone, brick, split face, sand blasted, or burnished concrete masonry units (CMU), projecting a mimmum depth of one inch from the primary facade of the building Alternative masonry materials include tile, wood siding, shakes, or metal panels 10 d Step Backs Recessing the top story(s) of the fagade a minimum of five (5) feet from the lower story(s) primary fagade(s) C Architectural Elements Buildings in multifamily residential development parcels shall be designed in accordance with the following standards Four (4) Sided Architecture All buildings and structures within a multifamily development parcel shall utilize the same fagade design elements, utilized the same materials and roof materials and articulation and modulation treatment on all building facades, including the use of paint colors 2 Quality Mixed income multi -family development parcels that include both affordable residential units and market rate residential units are required to be constructed using the same fagade articulation and modulation treatment, fagade colors, and -materials such that the facades of affordable and market rate units are indistinguishable 3 Private Open Space Amenity All first (1) floor residential units shall include a private terrace or patio All upper floor residential units shall include a private balcony or rooftop terrace 4 Architectural Projections All building facades and/or roofs shall include a minimum of two (2) of the following features above the first (1) floor of the building along all street frontages as illustrated in Figure 18 64 050 G The horizontal distance between features shall be no greater than twenty-five (25) feet The minunum width and depth of these features shall be as follows a Greenhouse or garden windows- must be at least eight (8) inches in depth at the farthest point from the primary facade of the building, and five (5) feet in width b Bay Windows- must be at least ten (10) inches in depth measured at the farthest point, and five feet in width c Roof dormers- must be at least two (2) feet in depth measured at the farthest point from the roof surface of the building, and four (4) feet in width d Balconies and Rooftop decks- must be at least five (5) feet in depth and ten (10) feet in width 11 Figun 1S 64 050 G Fifty feet minimum A. Recesses or projections 0 B Horizontal banding C. Masonry base ® D Step back 5 Blank Walls First floor facade without doors or windows shall be no greater than two hundred (200) square feet where fronting sidewalks, multi -use paths, or publicly accessible outdoor common space areas Blank wall frontages shall include front or side yard setback landscape screening foundation planting beds that must be a minimum of three (3) feet in width for the entire facade length 6 Blank Wall Standards Blank walls shall be mitigated where it is infeasible to provide openings, such as a parking garage, trash room, mechanical room, or electrical room One of the following treatments shall be provided for any blank wall greater than twenty (20) feet in length a Wall treatment Wall treatment in the form of permitted graphic or sculptural art, decorative ceramic tile, or painted metal or treated wood latticework combined with living plant material shall be provided along the blank wall A minimum of fifty (50) percent of the blank facade shall be treated b Surface texture Surface articulation that recesses or projects a minimum of two (2) inches from the face of the primary facade shall be provided Stone, stone veneer, cast in place or precast concrete, and finished concrete block are permitted surface treatments A minimum of fifty (50) percent of the blank facade shall be treated 12 c Screen Landscaping Planting in the form of any combination of climbing vines, perennials, annual flowers, decorative grasses or shrubs, shall be provided in planting beds, raised planting beds or planter boxes in front of the blank wall Such planting bed or planter boxes shall extend to a depth of at least three (3) feet, inclusive of any structure containing the planted material Any individual planted area shall have a width and height of at least five (5) feet at time of landscape installation A mimmum of fifty (50) percent of the blank facade shall be screened by planted material D Building Colors and Materials 1 Primary Facade Material Building primary facades shall be wood, stone, brick, stucco, fiber cement or other cementitious material, or composite wood or stone 2 Secondary Facade Material At least two (2) secondary facade materials shall be used on all building facades 3 Building Color Buildings shall have a minimum of one (1) primary facade color, one (1) secondary facade color, and two (2) accent window and door frame, or trim colors, and one (1) roof color 4 Facade Color Standards Facade colors shall be select that are appropriate for Grand Terrace's Inland Empire setting Paint color and finish shall be muted and flat to imitate colors found naturally in nearby Blue Mountain soil, trees, rocks, and other organic materials a The use of color and materials shall, strengthen and complement building vertical and horizontal modulation b All building facades shall be painted equally c Facade Colors The primary color and secondary colors shall be limited to warm white shades and rich, warm colors containing some brown (ranging from neutral tan to deep brown) The outer ring of the color wheel illustrates the range of colors that are of an earth tone and are acceptable for use Facade colors within the illustrated earth tone spectrum may vary in tmt and tone but are not allowed to use the hue (pure color) as illustrated in Figure 18 64 050 H 13 Figuav 18 64 050 H 5 Fenestration Color Standards Windows, doors, and trim shall be limited to a mimmum of two (2) and a maximum of three (3) paint colors a Window and door tnm is permitted to utilize all the tints and tones of the full color spectrum b Windows shall be limited to shades of black or warm colors containing deep brown c Doors shall be permitted to utilize the tints and tones of the full color spectrum d Prohibited Colors Trim, Doors and Windows are prohibited from utilizing the hue of any color 6 Color Sources Building shall use the hex color palettes identified as earth tones in Hexcolorpedia https //hexcolorpedia com/?s=earth+tonespage%2F2page%2F2page%2F2 or equivalent on-line color tool that provides information about earth tone color Buildings shall be limited to a Primary Building Fagade Colors The primary hex color tints, tones and shades b Primary Color Blending Blending two hex color values to create a gradual transition c Secondary Color Schemes Complementary, analogous, triadic, tetradic, aesthetic, hue rotation and monochromatic hex colors schemes 7 Prohibited Fagade Materials The following materials shall not be used for multi- 14 family residential building fagade Cladding shall include the following prohibited materials vinyl siding, corrugated fiberglass siding, chain link fencing parapet or mechanical equipment screens, crushed colored rock veneer panel siding, corrugated metal, engineered oriented OSB sheathing panels, tongue and groove and T1-11 plywood siding No more than five (5) percent of a fagade may be of reflective vision and/ or spandrel glazing, tumbled glass tiles, ceramic tiles or architectural metal paneling MDO or CDX grade or better weather protected painted or stained plywood panels used for board and batten cladding is permitted No cladding shall have exposed or unfinished edges 8 Windows True divided lite window types are permitted Simulated divided lite windows with decorative grilles embedded or applied to window glass glazing is prohibited Window tinting is prohibited 9 Doors Fifty (50) percent minimum transparent glass doors for multiple unit lobby entrances shall be required but shall not be required for individual residential unit entries 18 64 060 Site Design A At -Grade Parking Lots and Individual Residential Unit Parking Garages/Carports In addition to the requirements of Chapter 18 60 (Off -Street Parking), multifamily residential sites with at -grade parking lots, or where units are served by individual " residential unit garages/carports, shall be designed in accordance with the following 1 Location At -grade parking lots, parking spaces, or loading zones shall not be located between the building frontage and public streets If a site consists of multiple buildings, this standard only applies to the buildmg(s) fronting public streets At - grade parking lots shall only be located behind street fronting buildings 2 Pedestrian Access Publicly accessible six (6) foot minimum width sidewalks shall be provided through at -grade parking lots at a minimum of every four rows of parking or at a minimum of every one hundred thirty (130) feet, whichever is less Publicly accessible sidewalks shall be designed to connect to buildings with consolidated entries and linked to other public sidewalks, and publicly accessible sidewalks within the site All such pathways shall be clearly marked and differentiated from at -grade parking lot drive lanes areas by colored and or surface textured asphalt, unit pavers, or stamped concrete pavement treatment Public accessible sidewalks shall meet the nght-of- way established in the Grand Terrace, Circulation Element and shall include the required street landscape, per Municipal Code, Chapter 12 28-Street and Parkway Trees 3 Motor Vehicle Access At -grade parking lot motor vehicle access shall be taken from an any existing alley For sites without an alley, at -grade parking lot motor vehicle access shall be from a public street curb cut and driveway with the lowest roadway classification as identified in the Grand Terrace Circulation Element Alleys shall be considered part of the multi -family site and shall be maintained by the property owner as a condition of use 4 Garage Door Setback Individual residential unit parking garage doors that front the street shall be setback a minimum of five (5) feet behind the front primary fagade of the multi -family building or the front fagade of a covered porch or stoop that projects in front of the primary fagade 15 5 Garage/Carport Design Individual residential unit parking garages and/or carports shall include equivalent facade design elements, fenestration, material and color application as those of the residential buildings within the site B Structured Parking In addition to the requirements of Chapter 18 60 (Off -Street Parking), multifamily residential buildings that include structured parking shall be designed in accordance with the following standards 1 Screening Where multifamily building fronts public streets, structured parking shall not comprise more than fifty (50) percent of the first floor building width subject to the following a Any two hundred (200) square feet or greater facade shall include required facade articulation, landscaping, and/or other requirements of C Architectural Elements 5 Blank Walls 2 Ventilation Fagade natural exhaust ventilation openings shall be screened with wrought iron grilles and/or landscaping Ventilation openings shall not exceed twenty (20) percent of any street fronting first floor facade 3 Control and Access Mechanically or manually -controlled structured parking doors or gates shall be setback a minimum of forty (40) feet behind the back of a public sidewalk For mixed use buildings or sites, the use of controlled entrances shall be limited to the portion of a structured parking reserved for resident parking spaces At controlled structured parking driveway entrances, lanes shall be dimensioned to permit motor vehicle U-turns to allow a vehicle to exit without backing into the street Parking spaces provided for multi -family building guest, service and delivery use shall be provided outside of any controlled entrance parking structure C Site Access and Connectivity Multifamily residential site streets, sidewalks, and multi- use pathways shall include 1 Internal Sidewalks Sites shall provide unobstructed American with Disabilities Act (ADA) compliant five (5) foot minimum width surface separated by a minimum three (3) foot wide planting bed where fronting any building 2 Site Design For multi -family sites, the following standards shall apply as illustrated in Figure 18 64 060A a Internal Circulation Multi -family sites that include internal streets or driveways shall provide uninterrupted continuous vehicle and walking connections through the site and a mimmum of two (2) access points to fronting public streets or alleys and sidewalks b All site internal streets, driveways, alleys, sidewalks, and multi -use pathways shall align with all existing and planned streets, alleys, sidewalks, and multi -use pathways external and fronting to the site c Any internal site cul-de-sac or other dead-end street longer than three hundred (300) feet shall provide sidewalk or multi -use pathway connections between internal or external streets sidewalks or multi -use pathways d Multi -family sites shall not be greater than six hundred (600) feet in length, measured from any fronting cross -street centerline, alley center line, or side property line Walking and biking midblock access connections shall be I[: provided at distances no greater than three hundred fifty (350) feet measured from a cross -street center line, alley center line, or side property line to the mid - block sidewalk or multi -use pathway center line All connecting midblock sidewalks or multi -use pathways shall have a ten (10) feet minimum width Figtn-e 1S 64 060r7 a Internal circulation b External network connections c Pedestrian access d Bloch size ,(600' maximum) 17 D Landscaping and Common Open Space Amenities Multi -family buildings and sites shall comply with all open space requirements of each zoning district and the following additional site design standards 1 Minimum Requirements Sites shall include live landscape plant and/or mulch materials throughout except where paved parking lots, streets, driveways, sidewalks, patios, service or utility structures/ pads, recreation facilities, or water elements occur Live landscape planting will comprise a minimum of seventy-five (75) percent coverage and planted at fifty (50) percent (minimum) at installation 2 Minimum Size All site trees and shrubs shall be planted at a minimum of twenty- five (25) percent of full growth maturity Trees within landscaped areas shall be provided at a minimum size of 36-inch box, or a minimum 48-inch box if tree specimen has a 20-foot canopy 3 Concrete Surface Standards Multi -use pathways adjacent to common open space areas that include flat work concrete surfaces greater than mnety-six (96) square feet shall be poured in place concrete A mimmum of fifty (50) percent shall be a stamped, salt, or exposed aggregate finish or utilize multiple colors of concrete with no individual section having more than ninety- six (96) square feet of one color Stamped, or aggregate finish shall be used in high traffic areas 4 Other Landscape Requirements Landscape requirements not specifically stated on this Ordinance shall comply with the Municipal Code, Chapter 18 61- Landscape Requirements 5 Walls and Fences a Walls and fences within the front setback shall not exceed 3 feet in height b Concrete or Concrete Masonry Unit (CMU) Will be constructed with split faced or shot blast CMU, or stone veneer over precision block, or monolithic poured concrete with surface resembling either stone veneer, or split face finish, or monolithic poured concrete with raised or depressed patterns of at least one half inch (1/2") covering 50% of the surface c Fences must be constructed of cedar or vinyl materials All posts must have caps Acceptable type of wood fence are illustrated in Figure 18 64 060 B Figure 18 64 060 B Shadowbox Pickets no more than 48" high Horizontally fixed planks Board on Board iaath top and bottom rail Cedar or redwood vertical planks with 25% of the upper portion of the fence in framed latticework 1i�ti illi{�i d Other fences include 1 Wrought iron or decorative iron, must have twelve (12) inches by twelve (12) inches pilaster a mimmum of every ten (10) feet u Brick, stone, or brick or stone veneer over precision block ui Glass fencing panels iv Columns of brick, stone, stone veneer or CMU as above no more than ten (10) feet apart with any of allowed fencing materials between the columns 6 Multi -family development sites shall comply with the parkway requirements included on Chapter 12 28 — Street and Parkway Trees 7 Common Open Space Standards (parkway requirements) Common open space resident amenities areas shall have a minimum dimension of 15 feet in depth and width and shall be contiguous to accommodate passive individual or group active recreational activity areas 8 Common Open Space Siting Criteria Location of common open space amenity areas shall be determined by the following siting criteria a Equal distance or less to no less than fifty (50) percent of all residential units within the multifamily building or site b Solar orientation Preferred Option- oriented no more than thirty (30) degrees off of a true south facing axis line Alternative Option- oriented no more than thirty (30) degrees off of a true east or west facing axis line Prohibited- oriented off a north facing axis line 19 c Screening Visually obstructed from first floor windows, streets, service areas and parking lots with a mimmum five (5) wide landscaped planting bed and/or fencing excluding chain link materials All fencing shall be subject to the height limitations of the zoning district and requirements of Chapter 18 73 070 (Fences and Wall Height) 9 Required Common Open Space Amenities Common open space areas shall be designed to provide specific amenities as shown in Table 18 64 060A based upon the number of units within a multifamily residential development The required amenities outlined in Table 18 64 060B are additive and require that the Base Amenity Type and Minimum Size of Amenity be satisfied for the applicable number of units threshold, plus all preceding Base Amenity Type and Minimum Size of Amenity Type, plus any additional increase in number or size of the amenity based upon the Additive Amenity Ratio As an example, a multifamily residential development consisting of 16 units shall provide a business center with at least two work stations or a 250 square foot gym, plus an outdoor active use area or facility, plus 48 square feet of community garden area (32 sf + 16 sf), and two barbecue areas with seating Table 18 64 060A Multifamily Residential Development Amenity Standards # Of Base Amenity Type Additive Amenity Ratio Unit And Minimum Size of s Amenity 4 Barbecue with table seating 1/10 Units 8 32 sf Community Garden 8 sf/4 Units 12 1200 sf Outdoor Active Use Area 50 sf/1 Unit Provide One of Two 16 • Business Center with 2 Work Stations • 1 Workstation/8 Units • 250 sf of G • 5sf/I Unit Provide Two of Three 24 - Business Center with 3 Work Stations • 1 Workstation/8 Units • 290 sf Gym • 5sf1I Unit • Clubhouse with 400 sf Kitchen • 5sf/I Unit Provide all of the following 32 • Business Center with 4 Work Stations • 1 Workstation/8 Units • 290 sf Gym • 5sf/I Unit • Clubhouse with 440 sf Kitchen • 5sf/I Unit 20 Table 18.64.060E Multifamily Residential Development Amenity Standards Number Base Amenity Type Additive Amenity Ratio of Units And Minimum Size of Amenity 40 Provide all Amenities listed as the Base for 32 Same rate as 32 Units 15 sf Units, and Provide Increase/ 1 Unit > 100 Units • One 36 SF In -Ground Outdoor Spa Provide all Amenities listed as the Base for 40 Same rate as 40 Units 65 Units, and Provide One of Two • 800 sf Pool • 10sf/1 Unit • 1000 sf Children's Play Areal • 10sf/1 Unit 80 All Amenities Listed as the Base for 65 Units Same Rate as 65 Units All Amenities2 Listed for 80 Units and Provide one of two 100 • One full sized Basketball Court • 1 Court + 75 Units • One full sized Tennis Court • 1 Court + 100 Units 150 All Base Amemties2 Listed for 100 Units Same Rates for All Apply Notes 1 Substitute 400 sf Wellness Facility 55+ Age Restricted Development, with an Additive Amenity Ratio calculated at 5 sf/1 Unit 2 Allows Wellness Facility Substitution. for 55+ Age Restricted Development 3 For 55+ Age Restricted Development May Substitute the Basketball Court with a Bocce Ball Court and/or replace the tennis Court with a Pickleball Court E Illumination Multifamily residential sites and building fagades shall comply with the following parking lot areas, pedestrian pathways, and building and structure exteriors illumination standards 1 Common Area/Pnvate Open Space All publicly accessible common areas and private residential open space areas shall comply with the illumination foot-candle (fc) level standards as follows a Service areas and vehicular traffic areas mimmum two tenths (0 2) fc, maximum four (4) fc b Sidewalks and building entries minimum one (1) fc, maximum five (5) fc, with an average of two (2) fc c Parking lot and area minimum one (1) fc, maximum four (4) fc 2 Sidewalks Sidewalk lighting shall have a maximum light pole and fixture height of fifteen (15) feet 21 3 Parking Lots Parking lot and area light fixtures shall be fully shielded and dark sky rated The light pole and fixture height shall be no greater than eighteen (18) feet above the parking lot finished grade 4 Accent Lighting Glare -free direct accent light fixtures with an illumination ratio of less than thirty to one (30 1) shall be permitted to highlight fagade articulation, artwork and landscape specimen plantings The extent of light coverage of all site light installations shall not exceed two (2) foot candle maximum illuminance impact on any fronting residential or commercial sites F Equipment and Service Areas Multifamily residential buildings and sites shall comply with the following equipment and service area standards 1 Underground All service connections and on -site utilities including wires, cable, and pipelines and equipment shall be installed underground 2 Roof -top Screening All exterior mechanical and electrical equipment, which includes, but is not limited to roof -mounted, fagade-mounted, or ground -mounted heating, venting, and cooling (HVAC) units, gas and electric utility meters, telecommunication equipment, backflow preventions, assemblies, irrigation control valves boxes, electrical transformers, pull boxes, and all HVAC ducting shall be screened Roof -mounted equipment shall not be visible from eye level at five (5) feet above grade of fronting streets centerlines and/or first floors of buildings within twenty (20) feet of the multi -family site property lines Screen fagades shall utilize the same fagade design elements, colors and materials of the building All roof - mounted equipment shall be screened from public view by screening materials of the same nature as the building Mechanical equipment shall be located below the highest vertical element of the building Ground mechanical equipment units shall be screened in a manner consistent with the building fagade 3 Ground -mounted Screening All ground -mounted mechanical equipment, shall not be visible from eye level at five (5) feet above grade from any publicly accessible open space (nghts-of- way, public trails, and parks) Screen fagades shall utilize the same design elements, colors and materials of the building 4 Refuse Standards Refuse collection and storage areas shall comply with the requirements of the City's service provider and the following standards a Utilization of individual dwelling unit refuse containers shall be limited to buildings of four (4) units or less The containers shall be stored within an unobstructed area of each resident's assigned parking garage space or within a common enclosed refuse container structure that utilizes the same fagade design elements, materials, and colors of the residential building b For multifamily residential buildings consisting of five (5) or more units, common container areas shall be provided and comply with the following standards 1 An enclosed refuse container structure that utilizes the same fagade design elements, materials, and colors of the residential building(s) ii Enclosed structure(s) shall be separated by a minimum of twenty (20) feet from any dwelling unit located within the multifamily residential site or from any property line 22 ill The enclosed structures shall be located a maximum of one hundred (100) feet distance from the dwelling units served iv Trash enclosures shall be completely sheltered by a roof v No minimum distance from dwelling units is required if the containers are located within a fully enclosed refuse room of a residential building The enclosed refuse room shall be located a maximum of seventy (75) feet from the dwelling units served vi Refuse container structures shall comply with Burrtec requirements 18 64 070 Additional Standards A Electric Vehicle Charging Stations (EVCS) Standards A minimum of one (1) Electric Vehicle Supply Equipment (EVSE) per garage and one (1) EVSE per five parking spaces will be required on a multi -family building site Parking spaces shall be exclusively dedicated for Electric Vehicle (EV) charging use 1 Minimum Space Requirements A parking space served by EVSE shall count as one (1) parking space for the purpose of complying with any applicable minimum parking space requirements for multi -family development as established by the Municipal Code Chapter 18 60 030 Off-street Parking Regulations 2 Electric Vehicle Charging Space (EV Space) Locations Where undedicated/guest parking is provided at least one EV space shall be located in the common use parking area and shall be available for use by all residents or guests All EV spaces shall be located under a weather protected carport, within a parking structure, or private garage Electrical equipment shall be located in areas that are well drained and shield from any landscape bed irrigation spray 3 Accessibility EV parking spaces shall comply with at least one of the following options a The EV space shall be located adjacent to an accessible parking space meeting the requirements of the California Building Code, Chapter 11A, to allow use of the EV charger from the accessible parking space b The EV space shall be located on an accessible route, as defined in the California Building Code, Chapter 2, to the building 4 Electric Vehicle Charging Space (EV Space) Dimensions The EV spaces shall be designed to comply with the following a The minimum length of each EV space shall be nineteen (19) feet b The minimum width of each EV space shall be nine (9) feet c Surface slope for accessible EV space and the aisle shall not exceed one (1) inch vertical in forty-eight (48) inches horizontal (2 083 percent slope) in any direction d Where vertical pole or pylon -mounted chargers are utilized, a mimmum of thirty- six (36) inches of clearance shall be provided to ensure safe and easy movement around the charging station 5 Level 2 Electric Charging Requirements A maximum of eighty (80) percent of 23 EVSEs shall have a minimum 40-ampere 208/240-volt dedicated EV branch circuit and shall be installed in close proximity to the proposed location of an EV charger, in accordance with the California Electrical Code 6 Direct Current Fast Charging (DCFC) with Combo Connector Requirements A minimum of twenty (20) percent of EVSEs shall have a minimum 40-ampere 208/240-volt dedicated EV branch circuit and shall be installed in close proximity to the proposed location of an EV charger, in accordance with the California Electrical Code 7 Smart Metering Separate or sub -metering that allows electricity used to be isolated from the rest of the building's energy use shall be provided 8 Signage and Wayfinding All EV parking spaces shall be identified as EV ONLY with a vertical pole or wall sign, and pavement shall be marked with a EV painted symbol as well Manual on Uniform Traffic Control Devices (MUTCD) compliant signs shall be provided for reserved American Disabilities Act (ADA) accessible EV spaces Additional information for tenant EVSE use including time limits for charging and enforcement, safety information, and host -operator information shall be provided 9 Host -Operator Agreements The building owner/operator or Home Owner Association (HOA) shall be responsible for establishing any agreements and costs associated with EV charging for tenants 10 Equity A mimmum of ten (10) percent of electricity generated from solar panels installed on carports over EV spaces shall be credited to low income tenants for EVSE use Host -Operator Agreements shall identify qualifications and process for low income tenants EV use B Public Art Standards All multi -family development(s) shall comply with Ordinance 343, Chapter 18 81 Art in Public Places of Title 18 of the Municipal Code C Bicycle Parking Standards These standards ensure that required bicycle parking is designed so people of all ages and abilities can access the bicycle parking and securely lock their bicycle Bicycle parking shall be provided in areas that are safeguarded from theft and accidental damage The standards allow for a variety of bicycle types, including but not limited to standard bicycles, tricycles, hand cycles, tandems, electric motor assisted cycles and cargo bicycles 1 Minimum Bicycle Parking Requirements Long-term bicycle parking shall be provided in secure, weather protected facilities for multi -family building residents who need bicycle parking for several hours or longer Short-term bicycle parking shall be located in publicly accessible, highly visible locations that serve the main entrance of a multi -family building Short-term bicycle parking shall be visible to bicyclists on the street and is intended for visitors Amounts of required long-term and short-term bicycle parking shall be provided as follows a Long term Requirement Multi -family buildings with 5 or more units, shall provide one (1) space per unit 1 In -unit allowance standards For sites with 20 or fewer units, up to 100% W, of bicycle parking spaces are permitted to be in dwelling units ii For sites with more than twenty (20) units, up to 20% of bicycle parking are permitted in dwelling units ui Elderly or disabled multi -family uses shall provide 1 bicycle parking space per 10 units b Long Term Additional Requirements Multi -family buildings with more than twenty (20) units, shall include 1 Cargo or long tail bicycle parking A mimmum of five ( 5) percent of bicycle spaces shall be provided for larger bicycles u Electrical bicycle charging A minimum of five (5) percent of spaces shall have access to electrical outlets c Short Term Requirement Multi -family buildings with more than twenty (20) units shall provide a minimum of one (1) space per twenty units 2 Uniform Standards for All Bicycle Parking Where long-term and short-term bicycle parking must be provided in lockers or racks, the following standards shall be met a Bicycle parking area The area devoted to bicycle parking must be hard surfaced b Bicycle Racks Racks must be designed so that the bicycle frame and one wheel can be locked to a rigid portion of the rack with a U-shaped shackle lock when both wheels are left on the bicycle Bicycle Parking Space, Maneuvering Area, and Clearance Dimensions Bicycle parking spaces, aisles and clearances must meet the minimum dimensions of the following 1 Standard Bicycle Parking Spaces Requirements The standard required bicycle space is two (2) feet in width, six (6) feet in length and three (3) feet four (4) inches in height There must be at least five (5) feet behind all bicycle parking spaces to allow room for bicycle maneuvering Where short- term bicycle parking is adjacent to a sidewalk, the maneuvering area may extend into the nght-of-way, A wall clearance of two (2) feet six (6) inches must be provided A mimmum of one (1) foot five (5) inches shall be provided between spaces u Vertical Bicycle Parking Spaces Requirements Vertical bicycle parking secures the parked bicycle perpendicular to the ground is permitted as an alternative to standard spaces The vertical required bicycle space shall be two (2) feet in width, six (6) feet in height and two (2) feet in depth There must be at least 5 feet behind all bicycle parking spaces to allow room for bicycle maneuvering A minimum of one (1) foot five (5) inches shall be provided between spaces ui Stacked Bicycle Parking Spaces Requirements Stacked bicycle parking are racks that are stacked, one tier on top of another are permitted as an alternative to standard spaces Bicycles shall be horizontal when in the final stored position The rack must include a mechanically -assisted lifting mechanism to mount the bicycle on the top tier There must be at least 5 feet behind all bicycle parking spaces to allow room for bicycle 25 maneuvering A minimum of one (1) foot five (5) inches shall be provided between spaces iv Larger Cargo or Long Tail Bicycle Parking Spaces Requirements These standard space dimensions shall be ten (10) feet in depth by three (3) feet in width by three (3) feet four (4) inches in height At least 5' feet behind the pace shall be provided for maneuvering A minimum of one (1) foot five (5) inches shall be provided between spaces d Bicycle Lockers Bicycle lockers that are fully enclosed and secured are permitted The locker must be anchored to the ground, and an aisle a minimum width of five (5) feet in width behind all bicycle lockers to allow room for bicycle maneuvering shall be provided The locker space shall have a mimmum depth of 6 feet and an access door that is a minimum of 2 feet in width 1 One (1) bicycle locker with one hundred and twenty (120) volt ac power per four (4) units and one (1) bicycle rack parking per every four (4) dwelling units no more than one hundred (100) feet from furthest unit served 3 Standards for Long -Term Bicycle Parking Long-term bicycle parking must be provided in lockers or racks that meet the following standards a Security Standards Long-term bicycle parking must be provided in one or more of the following 1 A restricted access, lockable room or enclosure, designated exclusively for bicycle parking u A bicycle locker ill In a residential dwelling unit b In-umt Parking Standards Long-term bicycle parking spaces may be provided in a dwelling unit if following conditions are met 1 The residential unit shall include a dedicated bicycle parking area that meets the standard bicycle parking spacing dimensions above 11 For buildings with no elevators, long-term in -unit bicycle parking shall be permitted only for first floor units 11 Balconies, terraces, or patios are prohibited for in-umt parking iv Signage Standard If bicycle parking is not visible from the public realm, a sign must be permanently posted at the main building or site entrance indicating the location of the bicycle parking 4 Standards for Short-term Bicycle Parking Short-term bicycle parking must meet the following standards a Location Bicycle parking must be on -site, outside the building, at the same grade as the sidewalk or at a location that can be reached by an accessible route b Main Entrance Proximity The bicycle parking must be within 50 feet of the main entrance to the building as measured along the most direct pedestrian access route 26 18 64 080 Additional Mixed Use Standards A Conformance with Standards and Requirements Mixed -use sites and buildings that include residential dwelling units shall comply with both development standards of the zoning district and all applicable multi -family design standards of this Chapter B Low Income Units Developments proposing twenty (20) residential units or more are required to provide ten (10) percent low income units or five (5) percent very -low income units No in -lieu fee shall be accepted C Off-street Parking Mixed use sites shall comply with all requirements of the Municipal Code Chapter 18 60—Off-Street Parking D Ground Floor Use and Height First floor residential dwelling units shall be prohibited along street facing building frontages The minimum first floor commercial building height shall be fourteen (14) feet, measured from the first finished floor elevation to the second floor finished floor or rooftop elevation Upper floor to floor heights shall be no greater than the first floor height E First Floor Window and Door Transparency All non-residential first floor street fronting uses shall comply with all applicable standards 1 Commercial or retail uses exterior walls facing a street shall include window and door openings that comprise a mimmum of seventy-five (75) percent of the first floor primary facade area, measured vertically between two and eight feet above the finished grade of fronting public sidewalks and horizontally only where first floor conditioned commercial tenant space occurs along the fronting facade 2 Office, hotel, and other non-residential uses exterior walls facing a street shall include window and door openings that comprise a minimum of seventy-five (75) percent of the first floor primary facade area, measured vertically between two (2) and eight (8) feet above the finished grade of fronting public sidewalks and horizontally only where first floor conditioned office, hotel, and other non- residential use tenant space occurs along the fronting facade 3 First (1) floor conditioned tenant space shall include window and/or door openings spaced no greater than ten (10) feet apart measured horizontally along the street facing primary building facade Reflective, tmted, or mirrored window glazing that prevents views of interior work areas, sales areas, lobbies, or storefront displays at a mimmum five (5) foot depth from the face of the primary first facade is prohibited F Storefront Treatment First (1) floor non-residential building fagades shall comply with all applicable standards listed and illustrated in Figure 18 64 070A 1 Awnings and Canopies Awnings or canopies shall not extend horizontally beyond first floor non-commercial use window and door openings Awning and canopy structural hardware shall not be lower than eight (8) feet above the fronting sidewalk finished grade elevation Signage or branding graphics of any type are prohibited on the exterior surface of the awning or canopy 2 Base Panels A wood, metal, or masonry base panel shall be provided across the entire width of the storefront window system and between any vertically articulated primary facade projections or recesses The base panels shall be no greater than twenty-four (24) inches in height, measured from the bottom of the sill of the window 27 system to the adjacent sidewalk finished grade 3 Signage A projecting or recessed tenant signage horizontal molding band or frieze shall be provided to articulate the top of only buildings with multiple storefronts All tenant signage shall comply with all applicable requirements of Chapter 18 80 (Signs) Fig u e 18 64 070A Q 1 Awning height M 2 Base panel 0 3 Horizontal band 18 64 090 Permits and Approvals A Ministerial Action The review of and action on the design of multifamily residential development or mixed -use development with a residential component that complies with the provisions of this Chapter is amimsterial action not subject to further discretionary review or action The Director has the authority to review applications for completeness and compliance with the provisions of this Chapter 1 Ministerial design review shall be administered through the Precise Plan of Design requirements as outlined in Chapter 18 63 (Site and Architectural Review), unless modified herein by this Chapter, and shall not require public notice, public hearing or be subject to any required findings for approval 2 Ministerial design review approval by the Director shall determine that the proposed application and plans a Complies with all applicable design standards of this Chapter b Complies with all applicable development standards of Title 18 (Zoning) without requiring a Minor Deviation or Variance If the Director is unable to make the above determination, review of the project design shall be subject to all application types, reviews and procedures as outlined in Chapter 18 63 (Site and Architectural Review) 3 The Director may, from time to time, provide a summary report as an informational item, to the Planning Commission, of any ministerial design review action on a development proposal subject to the provisions of this Chapter No action by the Planning Commission shall be required B Other Application Submittals and Types of Review The following other types of application submittals and types of review may also apply, subject to the provisions outlined in this Section 1 The SB 330 Preliminary Application review process is an additional review by the Director and provides early identification of all standards and requirements applicable to a project A review under this procedure is subject to all requirements and information and materials listed on the City's SB 330 Preliminary Application The availability of this type of review shall sunset on January 1, 2025, unless extended by the State legislature The preliminary application review process is at the option of a project proponent and may only be implemented when all requirements of this Chapter are satisfied, including all timeframes required for submittal of a formal application 2 If a development qualifies under the Senate Bill 35 eligibility cntena as outlined in this Section, information and materials as listed on the City's SB 35 Application (Affordable Housing Streamlined Review) shall be submitted for review by the Director to determine eligibility 3 The provisions, including any requirement for review, hearing and action for Minor Deviation as provided in Chapter 18 89 (Minor Deviations), Variance as provided in Chapter 18 86 (Variance), or Conditional Use Permit as provided in Chapter 18 83 shall apply to any multifamily residential development or mixed - use development with a residential component that proposes to deviate from any standard of this Chapter and when it is a requirement established by the proposed commercial use Such deviation shall null and void any ministerial design review action or eligibility for an affordable housing streamlined review process 4 All development shall be required to comply with San Bernardino County Fire (SBCF) standards and requirements All infill development and tenant improvement projects subject to ODS standards shall be required to submit to SBCF to obtain conditions of approval for the project 5 For multifamily development with mixed uses that include restaurants, all 29 clearances with San Bernardino County Health Department shall be obtained C Building Permit All development subject to the requirements of this Chapter shall require a Building Permit, subject to all the standard application, review and processing fees and procedures that apply to Building Permits generally D Fees All development subject to the requirements of this Chapter shall be accompanied by the required application fee Application fees are established by Council resolution E Preliminary Application In compliance with Government Code Section 65941 1, a proponent of a multifamily residential development or mixed -use development with a residential component has the option of submitting a Preliminary Application subject to all the following requirements 1 All of the information listed in City's SB 330 Preliminary Application form and payment of the Preliminary Application processing fee shall be submitted to the City 2 If the City determines that the Preliminary Application for the development project is incomplete, the project proponent must submit the specific information needed to complete the application within 90 days of receiving the City's written identification of the necessary information If the project proponent does not submit this information within the 90-day period, then the preliminary application shall expire and have no further force or effect, and if any portion of the ministerial design review was completed or approved, it shall be deemed null and void After submittal of all of the information required, if the project proponent revises the project to change the number of residential units or square footage of construction changes by 20 percent or more, excluding any increase resulting from Density Bonus Law, the development proponent must resubmit the required information so that it reflects the revisions 4 The project proponent shall submit a formal application for a development project within 180 calendar days of submitting a complete preliminary application If the City determines that the formal application for the development project is incomplete, the project proponent shall submit the specific information needed to complete the application within 90 days of receiving the City's written identification of the necessary information If the project proponent does not submit this information within the 90-day period, then the preliminary application shall expire and have no further force or effect, and any such ministerial design review approval shall be deemed null and void 5 If the applicant revises the project between the Preliminary Application phase and the formal application phase, such that the number of residential units or square footage of construction changes by 20 percent or more, exclusive of any increase resulting from the receipt of a density bonus, incentive, concession, waiver, or similar provision, the project shall not be deemed to have submitted a Preliminary Application, in satisfaction of State and City requirements, until the project proponent resubmits the required information, and if any portion of the ministerial design review was completed or approved, it shall be deemed null and void 6 Compliance with all applicable provisions of this Chapter, specifically, the process 30 and timeframes outlined in this Section, shall constitute a ministerial design review approval in conjunction with the Preliminary Application review if the Director determines that the proposed application and plans a Complies with all applicable design standards of this Chapter b Complies with all applicable development standards of Title 18 (Zoning Code) without requiring a Minor Deviation, Variance, or Conditional Use Permit If the Director is unable to make the above determination, review of the project design shall be subject to all application types, reviews and procedures as outline in Chapter 18 63 — Site and Architectural Review Additional review procedures may be required 7 The Director may, from time to time, provide a summary report as an informational item, to the Planning Commission, of SB 330 Preliminary Application reviews and associated ministerial design review action on a development proposal subject to the provisions of this Chapter No action by the Planning Commission shall be required F Affordable Housing Streamlined Review Eligibility Criteria In compliance with Government Code Section 65913 4, also known as Senate Bill 35 (SB 35), a qualifying multifamily housing development project may submit to the Director a request for an affordable housing streamlined approval The Director will determine if the project is eligible for streamlined approval within 60 days after application submittal for projects of 150 or fewer units, or within 90 days for larger projects If the Director denies the application as incomplete or ineligible for SB 35, the applicant may revise the project to comply with SB 35 and resubmit the application, subject to the same timeline for review Once the application is accepted for review under SB 35, the Director will approve or deny the project within 90 days after application submittal for projects of 150 or fewer units, or within 180 days for larger projects To be eligible for streamlined processing under SB 35, the development project must satisfy all of the following criteria 1 The project must be a multifamily housing development that contains at least two residential units and comply with the minimum and maximum residential density range permitted for the site, plus any applicable density bonus 2 If more than ten residential units are proposed, at least ten percent of the project's units must be dedicated as affordable to households making below 80 percent of the area median income If the project will contain subsidized units, the applicant has recorded or is required by law to record, a land use restriction for either a minimum of 55 years for rental type units, or a mimmum of 45 years for ownership type units 3 The project must be located on a legal parcel or parcels within the incorporated City limits At least 75 percent of the perimeter of the site must adjoin parcels that are developed with urban uses, which means any current or former residential, commercial, public institutional, transit or transportation passenger facility, or retail use, or any combination of those uses Parcels that are only separated by a street or highway shall be considered adjoined 4 The project must be located on a site that is either zoned or has a General Plan designation allowing for multifamily residential development or mixed -use development with a residential component 5 The project must meet all objective design standards in effect at the time the application 31 is submitted 6 The project must provide at least one parking space per unit without regard to unit size, number of bedrooms, or guest parking spaces, however, no parking is required if the project meets any of the following cntena a The project is located within one-half mile of public transit b The project is located within an architecturally and historically significant historic district c On -street parking permits are required but not offered to the occupants of the project d There is a car share vehicle within one block of the development 7 The project must be located on a property that is outside each of the following areas a Either prime farmland or farmland of statewide importance, as defined pursuant to United States Department of Agriculture land inventory and monitoring criteria, as modified for California, and designated on the maps prepared by the Farmland Mapping and Monitoring Program of the Department of Conservation, or land zoned or designated for agricultural protection or preservation by the City b Wetlands, as defined in the United States Fish and Wildlife Service c A very high fire hazard seventy zone, as determined by the Department of Forestry and Fire Protection, or within a high or very high fire hazard seventy zone as indicated on maps adopted by the Department of Forestry and Fire Protection pursuant to Section 4202 of the Public Resources Code d A hazardous waste site that is listed pursuant to Section 65962 5 or a hazardous waste site designated by the Department of Toxic Substances Control pursuant to Section 25356 of the Health and Safety Code, unless the Department of Toxic Substances Control has cleared the site for residential use or residential mixed - uses e A delineated earthquake fault zone as determined by the State Geologist in any official maps published by the State Geologist, unless the development complies with applicable seismic protection building code standards adopted by the California Building Standards Commission under the California Building Standards Law (Part 2 5 (commencing with Section 18901) of Division 13 of the Health and Safety Code), and by any local building department under Chapter 12 2 (commencing with Section 8875) of Division 1 of Title 2 f A flood plain as determined by maps promulgated by the Federal Emergency Management Agency, unless the development has been issued a flood plain development permit pursuant to Part 59 (commencing with Section 59 1) and Part 60 (commencing with Section 60 1) of Subchapter B of Chapter I of Title 44 of the Code of Federal Regulations g A floodway as determined by maps promulgated by the Federal Emergency Management Agency, unless the development has received a no-nse certification in accordance with Section 60 3(d)(3) of Title 44 of the Code of Federal Regulations h Lands identified for conservation in an adopted natural community 32 conservation plan pursuant to the Natural Community Conservation Planning Act (Chapter 10 (commencing with Section 2800) of Division 3 of the Fish and Game Code), habitat conservation plan pursuant to the Federal Endangered Species Act of 1973 (16 U S C Sec 1531 et seq ), or other adopted natural resource protection plan Habitat for protected species identified as candidate, sensitive, or species of special status by State or Federal agencies, fully protected species, or species protected by the Federal Endangered Species Act of 1973 (16 U S C Sec 1531 et seq ), the California Endangered Species Act (Chapter 15 (commencing with Section 2050) of Division 3 of the Fish and Game Code), or the Native Plant Protection Act (Chapter 10 (commencing with Section 1900) of Division 2 of the Fish and Game Code) J Lands under conservation easement k A site that would require demolition of housing that is subject to recorded restrictions or law that limits rent to levels affordable to moderate, low, or very - low -income households, subject to rent control, or currently occupied by tenants or that was occupied by tenants within the past ten years 1 A site that previously contained housing occupied by tenants that was demolished within the past ten years in A site that would require demolition of an historic structure that is on a local, State, or Federal register n A parcel of land or site governed by the Mobilehome Residency Law, the Recreational Vehicle Park Occupancy Law, the Mobilehome Parks Act, or the Special Occupancy Parks Act 8 The project does not involve an application to create separately transferable parcels under the Subdivision Map Act 9 The project proponent must certify to at least one of the following a The entirety of the project is a public work as defined in Government Code Section 65913 4(8)(A)(1) b The project is not in its entirety a public work and all construction workers employed in the execution of the development will be paid at least the general prevailing rate of per diem wages for the type of work and geographic area c The project includes ten or fewer units, is not a public work and does not require subdivision 10 If the project consists of 50 or more units that are not 100 percent subsidized affordable housing, the project proponent must certify that it will use a skilled and trained workforce, as defined in Government Code section 65913 4(8)(B)(11) 33 STATE OF CALIFORNIA COUNTY OF SAN BERNARDINO CITY OF GRAND TERRACE I Debra L Thomas, City Clerk of the CITY OF GRAND TERRACE, CALIFORNIA, DO HEREBY CERTIFY that the foregoing Ordinance, being Ordinance No 348 was duly passed, approved and adopted by the City Council, approved and signed by the Mayor, and attested by the City Clerk, at the regular meeting of said City Council held on the 28th day of March 2023, and that the same was passed and adopted by the following vote AYES Council Members Jeff Allen, Ken Henderson, Mayor Pro Tern Doug Wilson, and Mayor Bill Hussey NOES None ABSENT Council Member Sylvia Rodriguez -Robles ABSTAIN None Executed this 30th day of March, 2023, at Grand Terrace, California Debra L Thomas City Clerk` [SEAL] J v