Loading...
11-02-2017 CITY OF GRAND TERRACE PLANNING COMMISSION/SITE AND ARCHITECTURAL REVIEW BOARD AGENDA Council ChambersRegular Meeting6:30 PM The City of Grand Terrace complies with the Americans with Disabilities Act of 1990. If you require special assistance to participate in this meeting, please call the City Clerk's office at (909) 824-6621 at least 48 hours prior to the meeting. If you desire to address the Planning Commission during the meeting, please complete a Request to Speak Form available at the entrance and present it to the City Clerk. Any documents provided to a majority of the Planning Commission regarding any item on this agenda will be made available for public inspection in the City Clerk's office at City Hall located at 22795 Barton Road during normal business hours. In addition, such documents will be posted on the City's website at www.grandterrace- ca.gov<http://www.grandterrace-ca.gov CALL TO ORDER Convene the Meeting of the Planning Commission and Site and Architectural Review Board. Pledge of Allegiance. Roll Call Attendee NamePresentAbsentLateArrived Chairman Tom Comstock Vice Chair Tara Ceseña Commissioner Jeffrey Allen Commissioner Edward A. Giroux Commissioner Gregory A. Goatcher APPROVAL OF AGENDA City of Grand TerracePage 1 Agenda Grand Terrace Planning Commission/Site and Architectural Review Board November 2, 2017 PUBLIC ADDRESS Public address to the Commission shall be limited to three minutes unless extended by the Chairman. Should you desire to make a longer presentation, please make written request to be agendized to the Director of Planning and Development Services. This is the opportunity for members of the public to comment on any items not appearing on the regular agenda. Because of restrictions contained in California Law, the Planning Commission may not discuss or act on any item not on the agenda, but may briefly respond to statements made or ask a question for clarification. The Chairman may also request a brief response from staff to questions raised during public comment or may request a matter be agendized for a future meeting. A.PUBLIC HEARINGS 1. Variance 17-03, Administrative Site and Architectural Review 16-09 and Environmental 16-10 RECOMMENDATION: 1) Conduct a public hearing, and 2) Adopt A RESOLUTION OF THE PLANNING COMMISSION/SITE AND ARCHITECTURAL REVIEW BOARD OF THE CITY OF GRAND TERRACE CALIFORNIA, ADOPTING AN ENVIRONMENTAL EXEMPTION PURSUANT TO THE CALIFORNIA QUALITY ACT, GRANTING VARIANCE 17-03, AND APPROVING SITE AND ARCHITECTURAL REVIEW 16-09 FOR THE CONSTRUCTION OF A 3,646 SQUARE FOOT SINGLE FAMILY HOME ON A 1.29 ACRE LOT, LOCATED AT PALM AVENUE (APN: 0276-331-49) DEPARTMENT: PLANNING & DEVELOPMENT SERVICES City of Grand Terrace Page 2 Agenda Grand Terrace Planning Commission/Site and Architectural Review Board November 2, 2017 B.INFORMATION TO COMMISSIONERS C.INFORMATION FROM COMMISSIONERS ADJOURN Adjourn to the next scheduled meeting of the Planning Commission Site and Architectural Review Board to be held on November 16, 2017 at 6:30 p.m. than 14 calendar days preceding the meeting. City of Grand Terrace Page 3 A.1 AGENDA REPORT MEETING DATE:November 2, 2017 TITLE:Variance 17-03, Administrative Site and Architectural Review 16-09 and Environmental 16-10 PRESENTED BY:Sandra Molina, Planning & Development Services Director RECOMMENDATION:1) Conduct a public hearing, and 2) Adopt ARESOLUTIONOFTHEPLANNING COMMISSION/SITE AND ARCHITECTURAL REVIEW BOARD OFTHECITYOFGRANDTERRACE CALIFORNIA, ADOPTINGAN ENVIRONMENTAL EXEMPTION PURSUANT TO THE CALIFORNIA QUALITY ACT, GRANTING VARIANCE 17-03, AND APPROVING SITE AND ARCHITECTURAL REVIEW 16-09 FOR THE CONSTRUCTION OF A 3,646 SQUARE FOOT SINGLE FAMILY HOME ON A 1.29 ACRE LOT, LOCATED AT PALM AVENUE (APN: 0276-331-49) 2030 VISION STATEMENT: This item supports Goal 3 to Promote Economic Development. PROPOSAL: Yacoub Farsakh ("Applicant"), represented by Al Aguirre of A.K.A & Associates Inc., has filed an application to construct a 3,646 square foot single family home with a three car garage on a 1.29-acre lot, located at Palm Avenue. The property is zoned R1-20-V- Low Density Single Family Residential. A Site and Architectural Review application has been filed for the construction of the residence and a Variance has been applied for to deviate 5 feet from the garage side yard setback requirement and 12 feet and 3inches from the rear setback requirement. SITE AND SURROUNDING AREA: The Project Site is an irregular polygon. Most of the lot is rough terrain that slopes downward towards the south and west. The proposed residence will be constructed on the west side of the property which is flat due to previous grading. The property has frontage on Palm Avenue and the property is accessed from Palm Avenue through a 30 foot wide private road and utility easement shared by four existing properties. The surrounded uses are as follows: ZoningGeneral PlanExisting Land Uses Packet Pg. 4 A.1 NorthR1-20-V-Low Density Low Density ResidentialResidential Single Family Residential East R1-20-V-Low Density Low Density Residential Residential Single Family Residential South Hillside Residential Hillside Low Density Blue Mountain (vacant Residential land) West R1-20-V-Low Density Low Density Residential Residential Single Family Residential PROJECT DESCRIPTION: General Plan/Zoning Consistency The project site is designated Low Density Residential (LDR) on the General Plan Land Use Map. The proposed development is consistent with the Low Density Residential designation because it limits land uses to single family detached residential units. The proposed residence is located within the high landslide susceptibility area and the very high fire hazard zone on the Public Health and Safety Element. The Applicant has prepared a Geotechnical Investigation Report, and should it be required by Building and Safety, the applicant will prepare a slope stability analysis. The structure will be built in compliance with the requirements for fire resistive construction in the Building and Fire Codes. The proposed residence is also consistent with the Housing Element which encourages infill housing and private development of underutilized land for residential construction, by maintaining the physical character of existing low residential neighborhood. The proposed zoned is R1-20-V - Low Density Single Family Residential, this zone designation in intended for very low density residential uses. The proposed development is consistent with the zoning and it meets the development standards such as building height and lot coverage. The Applicant has applied for a Variance to deviate from the rear setback and garage side yard setback requirements. Site Plan and Grading The lot has rough terrain that slopes downward towards the south and east. The proposed area to be developed is located at the west side of the property on top of a relatively flat pad that was previously graded. There are no permits on file for the grading that was done on the property and a Condition of Approval has been added requiring the applicant to provide pad certification for the grading previously constructed and to insure slope stability. The Applicant will access the property from the terminus of Palm Avenue, onto a private Packet Pg. 5 A.1 road also identified as Palm Avenue. The road is a 30 feet private road and public utility easement that provides access and services to four existing properties. A portion of the ingress and egress easement, and a gate agreement. In addition, there is a 30-foot sewer easement that goes through the property. This sewer easement provides service to the property located to the west. There is a natural rock formation at the north-east corner of the property. Unstable rocks have previously fallen onto Palm Avenue damaging the street; therefore, Staff has included a condition of approval for the applicant to remove all loose and unstable rocks. Variance The residence entrance will face east, the front setback and south side yard setback are consistent with the setback requirements; however, the Applicant has submitted a Variance application to deviate from the 35-foot rear yard and the 10-foot garage side yard setback requirement. The Zoning Code requires that slopes exceeding five percent shall be permitted no closer to a residential structure than a distance equal to the required side and rear yard setbacks. Except that in the In the R1-20 zone district, the rear yard setback may include ten feet of slope that is greater than five percent. The table below illustrates the deficiency and purpose of the variance. Setback Required Proposed Deficiency Garage Side 0 From slope Rear From slope - The findings to support the Variance application are included in the attached Resolution. In particular there are special circumstances related to the location and topography of the lot. The lot is in a hillside area and is mostly made up of rough terrain that slopes downward towards the south and east. The topography limits the placement at the west side of the property on the only flat surface, which was previously graded, and which is near the down-sloping areas of the lot. Therefore, due to location and topography a special circumstance exists to support the variance. Further, the strict application of the zoning ordinance would deprive the property of privileges enjoyed by other properties, because the steep topography of the lot makes it infeasible to place the residence anywhere but the only flat area of the lot. Wet Utilities There is a sewer main line in the existing road easement that the Applicant will be required to tie in to. To serve the residence with water service, the Applicant will be required to connect the main line to the booster station located at the end of the access road. Architectural Elevations/Floor Plans Packet Pg. 6 A.1 The proposed residence has 2,600 square feet of livable space, including four bedrooms, two and one half bathrooms, living room, family room, dining room and kitchen. The house includes a 709 square foot three car garage, and a 114 square foot entry porch. The elevations show a one-story ranch style house enhanced by architectural details such as, multi pane windows, French doors, window and door decorative molding, and decorative veneer stone on front side of the house. The applicant is proposing weathered terra cotta eagle tile Capistrano style for the roof, the stucco will be a based cream color and the fascia and trim will be contrasted in brown. Conceptual Landscaping Plan The proposal includes a water efficient landscape including a water fountain at the entrance of the home, Staff has included a Condition of Approval for the water fountain to include a recyclable water system. The water fountain will be surrounded by mulch and shrubs delineating the walk areas leading to the door entrance. A row or shrubs also delineates the driveway entrance and the perimeter of the house. The landscape will also include crape myrtle trees along both sides of the driveway. Staff has also included a Condition of Approval requesting the applicant to increase the number of planting material. A final landscape and irrigation plan will be reviewed by the Planning Department and a Condition of Approval has been included for the applicant to increase the planting material on the proposed landscaping areas around the residence, and to the north planting area adjacent to the private road. AGENCY REVIEW: The Project Plans were distributed to various agencies and City Departments for review and comments. Conditions of approval from the City Building and Safety, Public Works Departments and County Fire are included in the resolution. ENVIRONMENTAL REVIEW: The Project to construct a single-story residence and three car garage is categorically exempt per the California environmental Quality Act, Code of Regulations, Title 14, Section 15303, which exempts the new construction of one single-family residence in a residential zone. PUBLIC NOTICE: Public notice of the hearing was published in Grand Terrace City News, posted in three public places and mailed to property owners within 300 feet of the site, in accordance with noticing requirements. To date, staff has not received any comments. CONCLUSION: The Proposed Project is consistent with the General Plan Land Use and Zoning designations. The granting of the Variance will not create negative impacts and the Packet Pg. 7 A.1 construction of the residence will complement the surrounding area. Staff recommends adoption of the attached Resolution approving the Project. ATTACHMENTS: PC Resolution_10.23.2017 (DOC) Resolution Exhibits (PDF) SA 16-09_Notice of Exemption (DOC) APPROVALS: Sandra Molina Completed 10/26/2017 6:04 PM City Attorney Completed 10/27/2017 12:26 PM Sandra Molina Completed 10/27/2017 1:04 PM Planning Commission/Site And Architectural Review Board Pending 11/02/2017 6:30 PM Packet Pg. 8 A.1.a RESOLUTION NO.17- A RESOLUTION OF THE PLANNING COMMISSION/SITE AND ARCHITECTURAL REVIEW BOARD OF THE CITY OF GRAND TERRACE CALIFORNIA, ADOPTING AN ENVIRONMENTAL EXEMPTION PURSUANT TO THE CALIFORNIA QUALITY ACT, GRANTING VARIANCE 17-03, AND APPROVING SITE AND ARCHITECTURAL REVIEW 16-09 FOR THE CONSTRUCTION OF A 3,646 SQUARE FOOT SINGLE FAMILY HOME ON A 1.29 ACRE LOT, LOCATED AT PALM AVENUE (APN: 0276-331-49) WHEREAS, Yacob Farsakh, represented by Al Aguirre of A.K.A. and Associates Inc., has filed applications for Variance 17-03 and Site and Architectural Review 16-09, requesting approval to construct a 3,646-square foot single family residence on 1.29- acre lot, located at Palm Avenue, identified as AParcel Number 0276-331-49. The site is zoned R1-20-V, Low Density Single Family Residential and Low Density Residential on the General Plan Land Use Map; WHEREAS, the Applicant has filed Variance 17-03 requesting a reduction of the rear setback and garage side yard setback requirements; WHEREAS, the Project qualifies for a categorically exemption, pursuant to Section 15303 of the California Environmental Quality Act (CEQA) Guidelines, which exempts the new construction of one single-family residence in a residential zone. WHEREAS, on November 2, 2017, the Planning Commission conducted a duly noticed public hearing on the Project at the Grand Terrace Council Chambers located at 22795 Barton Road, Grand Terrace, California 92313 and concluded the hearing on said date. WHEREAS, all legal prerequisites to the adoption of this Resolution have occurred. NOW THEREFORE, BE IT RESOLVED by the Planning Commission of the City of Grand Terrace: 1. The Planning Commission/Site and Architectural Review Board hereby finds that the Project is categorically exempt pursuant to Section 15303 from the provisions Attachment: PC Resolution_10.23.2017 \[Revision 4\] (SA 16-09, V 17-03 and E 16-10) of the California Environmental Quality Act (CEQA). The Notice of Exemption prepared in connection with the Project has been reviewed and considered and reflects the independent judgment of the Planning Commission/Site and Architectural Review Board, and is hereby adopted. 2. The Planning Commission/Site and Architectural Review Board finds as follows with respect to Variance 17-03: Packet Pg. 9 A.1.a a.A special circumstance regarding the size, shape, topography, location or surroundings of the subject property exists. The location and topography are very irregular. Most of the lot is a rough terrain that significantly slopes down towards the south and east, limiting the placement of the to the west side of the property on top of a relatively flat pad that was previously graded. The location and topography of the lot dictate the only area where the residence can be constructed and therefore the variance can be supported. b. Because of the special circumstance, the strict application of the zoning ordinance deprives the subject property of privileges enjoyed by other properties in the vicinity and under identical zoning classification. The strict application of the zoning ordinance would deprive the property of privileges enjoyed by other properties, because the steep topography of the lot makes it infeasible to place the residence anywhere but the only flat area of the lot. c. The granting of the Variance will not constitute the grant of special privileges inconsistent with the limitations upon other properties in the vicinity and district in which the property is situated. The topographical characteristics of the property limit the buildable area of the site. The only feasible location is the west side of the property on a previously graded pad; therefore, this Variance will not constitute the granting of special privileges. d. The granting of the Variance will not authorize a use or activity which is not otherwise expressly authorized by the district governing the parcel of property. The proposed project is consistent with the Zoning Map, which is intended for single family residences, and the granting of the Variance will not authorize a use that is not permitted by the R-1-20-V Low Density Single Family Residential. e. The granting of the Variance will not result in a situation inconsistent with the latest adopted of General Plan. The project is consistent with the Low Density Residential designation on the General Plan Land Use Map, which limits land uses to single family detached residential units. f. Conditions necessary to secure the above findings are made a part of the approval of the variance. Attachment: PC Resolution_10.23.2017 \[Revision 4\] (SA 16-09, V 17-03 and E 16-10) 3. The Planning Commission/Site and Architectural Review Board finds as follows with respect to Site and Architectural Review 16-09: a. The proposed residential project is consistent with the intent of the Grand Terrace Municipal Code and the General Plan. The project is zoned R-20- V-Low Density Single Family Residential, this zoning designation is intended for very low single family detached residential units. Per Zoning Code, the Project meets development standards relating to residential Page 2 of 8 Packet Pg. 10 A.1.a buildings, architecture, color, and scale. The Project also meets structural, building height and building coverage. The Applicant has filed for a Variance to deviate from the rear yard setbacks and side garage setback requirements. The project site is designated Low Density Residential (LDR) on the General Plan Land Use Map. The proposed development is consistent with the Low Density Residential designation because it limits land uses to single family detached residential units. The proposed residence is located within the high landslide susceptibility area and the very high fire hazard zone on the Public Health and Safety Element. The Applicant has prepared a Geotechnical Investigation Report, and should it be required by Building and Safety, the applicant will prepare a slope instability analysis. The structure will be built in compliance with the requirements for fire resistive construction in the Building Code as well as the San Bernardino County Fire Department regulations for high fire zone areas. The proposed residence is also consistent with the Housing Element which encourages infill housing and private development of underutilized land for residential construction, by maintaining the physical character of existing low residential neighborhood. b. The location and configuration of all structures associated with this Project are visually harmonious with this site and surrounding sites and structures, that they do not interfere with the neighbors' privacy, that they do not unnecessarily block scenic views from other structures and/or public areas, and are in scale with the townscape and natural landscape of the area. The architecture of the building will enhance the surrounding area, and will be visually harmonious. The proposed residence will be constructed a lower grade than the adjacent residences to the west and to the north, there are no properties located to the south, and the property located to the east is more than two hundred feet away; therefore, the proposed block scenic views. c. The architectural design of structures, their materials and colors are visually harmonious with surrounding development, natural landforms, are functional for the proposed project and are consistent with the Grand Terrace Municipal Code. The Project has included architecture elements Attachment: PC Resolution_10.23.2017 \[Revision 4\] (SA 16-09, V 17-03 and E 16-10) typical to ranch house style, such as multi pane windows, French doors, decorative molding, decorative stone accents and terra cotta tiles. The project will include a color scheme of earthy/neutral colors, Capistrano style tile and two foot of stone veneer accents on the front side of the house. The design and style of the structure, and the drought tolerant landscape will enhance the property and be visually harmonious with surrounding development. Page 3 of 8 Packet Pg. 11 A.1.a d. The plan for landscaping and open spaces provides a functional and visually pleasing setting for the structures on this site and is harmonious with the natural landscape of the area and nearby developments. The Project site will be landscaped in accordance with City and State regulations. The proposal includes water efficient landscape materials including mulch and shrubs delineating the walk areas leading to the door entrance. A row or shrubs also delineates the driveway entrance and the perimeter of the house. The landscape will also include crape myrtle trees along both sides of the driveway. These areas will be enhanced with additional landscaping as required in the Conditions of Approval. e. There is no indiscriminate clearing of property, destruction of trees or natural vegetation or the excessive and unsightly grading of hillsides, thus setting, and natural landforms are preserved. The property was previously graded which is where the structure will be built. Minimal additional grading will be required. One tree will be removed which is negligible. f. Conditions of approval for this project necessary to secure the purposes of the Grand Terrace Municipal Code and General Plan are made a part of this approval as set forth in the accompanying Resolution of Approval. BE IT FURTHER RESOLVED that Variance 17-03 and Site and Architectural Review 16-09 are hereby approved subject to the following conditions: 1. Variance 17-03 and Site and Architectural Review 16-09 are approved to construct a 3,646-square foot residential building consisting of four bedrooms and two and one-half bathrooms. The project site measures 1.29-acre lot located at the terminus of Palm Avenue, zoned R1-20-V Low Density Single Family Residential. This approval is based on the application materials submitted by Yacoub Farsakh, represented by Al Aguirre A.K.A & Associates Inc., on November 27, 2016, including color material board, Preliminary Geotechnical Investigation Report, and revised project plans dated September 06, 2017. The application materials are approved as submitted and shall not be altered unless reviewed and approved by affected departments. Attachment: PC Resolution_10.23.2017 \[Revision 4\] (SA 16-09, V 17-03 and E 16-10) th 2. If not appealed, this approval shall become effective on the eleventh (11) day after the da thth day following such eleventh (11) day when the eleventh (11) day is not a city business day. This approval shall expire twelve (12) months from the date of adoption of this resolution unless building permits have been issued and a substantial investment has occurred; all conditions of approval have been met; or a time extension has been granted by the City, in accordance with Chapter 18.63 Page 4 of 8 Packet Pg. 12 A.1.a of the Zoning Code. Timeextensions shall be filed at least sixty (60) days prior to the expiration date. 3. Minor modifications to this approval which are determined by the Planning Director to be in substantial conformance with the approved site plan, and which do not intensify or change the use or require any deviations from adopted standards, may be approved by the Planning Director upon submittal of an application and the required fee. 4. The applicant shall defend, indemnify, and hold harmless the City of Grand Terrace and its officers, employees, and agents from and against any claim, action, or proceeding against the City of Grand Terrace, its officers, employees, or agents to attack, set aside, void, or annul any approval or condition of approval of the City of Grand Terrace concerning this project, including but not limited to any approval or condition of approval of the Planning Commission, or Planning and Development Services Director. The City shall promptly notify the applicant of any claim, action, or proceeding concerning the project and the City shall cooperate fully in the defense of the matter. The City reserves the right, at its own option, to choose its own attorney to represent the City, its officers, employees, and agents in the defense of the matter. 5. Upon approval of these conditions and prior to becoming final and binding, the and content shall be prepared by the Community and Economic Development Department. 6. In the event that exhibits, and written conditions are inconsistent, the written conditions shall prevail. 7. The project shall be constructed in accordance with all the approved plans and conditions of approval, including but not limited to site plans, grading plans, floor plans, and building elevations, as they may be modified by these conditions of approval. 8. The applicant shall pay all applicable development impact fees, and demonstrate the payment of school impact fees to the Building and Safety Department. 9. Construction and operational activities associated with the project shall comply Attachment: PC Resolution_10.23.2017 \[Revision 4\] (SA 16-09, V 17-03 and E 16-10) Terrace Municipal Code. 10. The applicant shall comply with all requirements of the City of Grand Terrace Building and Safety Division, including the conditions of approval contained in the emorandum dated May 30, 2017, attached hereto as Exhibit 1. Page 5 of 8 Packet Pg. 13 A.1.a 11.The applicant shall comply with all requirements of the City of Grand Terrace Public Works Director, including the conditions of approval contained in the July 7, 2017, attached hereto as Exhibit 2. 12. The applicant shall comply with all requirements of the San Bernardino County Fire Department; Office of the Fire Marshal Community Safety Division, including the conditions of approval contained in Memorandum dated June 6, 2017, attached hereto as Exhibit 3. 13. The applicant shall comply with all the requirements of the, City of Colton Water and Wastewater Department, relating to sewer service requirements. 14. Prior to the issuance of building permits, the applicant shall provide a will service letter, and obtain all requisite permits and clearances from Riverside Highland Water Company (RHWCO). 15. The applicant shall show on the Site and Grading Plans proposed water main line improvements prior to construction. The applicant shall provide authorization from affected property owners for the construction of the water line extension. 16. Four (4) copies of the construction plans, including grading and site plans shall be submitted to the Building and Safety Division for review and approval, which shall include approval by the Planning and Engineering Divisions. 17. The applicant shall incorporate into the project design all existing easements within the project boundaries, or obtain abandonment of said easement from the affected easement holder(s). If this requirement cannot be accomplished, the project shall be redesigned. 18. The applicant shall provide a Pad Certification for the grading previously constructed and provide an engineered design to assure that slop instability will not impact the development. 19. The grading plan shall show the contour lines on the entire property including extending them ten (10) foot beyond the property liens. 20. Prior to grading or any site disturbance, the applicant shall prepare a slope instability analysis, should it be required by Building and Safety. Attachment: PC Resolution_10.23.2017 \[Revision 4\] (SA 16-09, V 17-03 and E 16-10) 21. The applicant shall prepare a slope instability analysis, should it be required by Building and Safety. 22. The applicant shall show drainage directed towards dissipation devices (rip rap) to mitigate potential erosion. No sheet flow allowed to drain onto slopes. 23. Air conditioning units shall be ground mounted. Page 6 of 8 Packet Pg. 14 A.1.a 24. All ground mounted equipment, including utility boxes and backflow devices shall comply with all the utility and Fire Department requirements and be screened in a manner that does not impede traffic visibility. 25. The applicant shall include a color and material legend on the elevation drawings. 26. The location of all building-mounted light fixtures shall be shown on the elevations. A detail of said fixtures shall be shown on the elevations, and fixtures shall be decorative and complementary to the building architecture. 27. In conjunction with grading or any ground disturbance activities, the Applicant shall remove all loose and unstable rocks from the natural rock formation located on the north-east corner of the property, as determined by the Public Works Director. 28. Prior to the issuance of building permits, the applicant shall submit three (3) copies of landscape and irrigation plan Water Efficient Landscape Ordinance (Chapter 15.56) Landscaping Standards contained in Chapter 18.60 of the Zoning Code, State Model Ordinance to the Planning and Development Services Department for review and approval. The plans shall demonstrate the following: a. Incorporation of drip irrigation; b. The applicant shall increase the landscaping material on the proposed landscaping areas around the residence, and to the planting area located on the north side of the property adjacent to the private road. c. The applicant shall maintain the proposed landscaping at the driveway not to exceed three (3) feet in height. d. Submit a $2000 deposit for landscape review. 29. Access rights shall be granted to the City to allowing access over the private road easement for all emergency vehicles, including police and fire; and for public utility easements. The document(s) recording this access shall be prepared by the applicant for review and approval by the City Engineer, prior to recordation. Attachment: PC Resolution_10.23.2017 \[Revision 4\] (SA 16-09, V 17-03 and E 16-10) PASSED AND ADOPTED by the Planning Commission of the City of Grand Terrace, nd California, at a public hearing held on the 2 of November 2017. AYES: NOES: ABSENT: Page 7 of 8 Packet Pg. 15 A.1.a ABSTAIN: ATTEST: __________________________ __________________________ Debra Thomas Tom Comstock City Clerk Chairman Attachment: PC Resolution_10.23.2017 \[Revision 4\] (SA 16-09, V 17-03 and E 16-10) Page 8 of 8 Packet Pg. 16 A.1.b Building and SafetyConditions of Approval Date: May 30, 2017 Applicant:Yacoub Farsak, Al Aguirre, REP Address of Applicant: 2222 Kansas Ave, Suite K, Riverside, Ca 92507 Site Location: APN: 0276-331-49, Top of Palm Ave. Please provide four (4) construction plans and documents for review of the proposed project. Below is a list of the plans and documents Building and Safety will need forplan review. The initial plan review will take approximately three weeks on most projects.Plan review fees and permit fees will becharged at the time plans are approved and are ready to issue. Provide the following sets of plans and documents. Building and Safety submittal’s required at first plan review. (4)Architectural Plans (4)Structural Plans (2)Structural Calculations (4)Plot/Site Plans (4)Electrical Plans (4)Electrical Load Calculations (4) Plumbing Plans/Isometrics, Water, Sewer and Gas (4)Mechanical Plans (4)Mechanical Duct Layout Plans (2) Roof and Floor Truss Plans (2) Title 24 Energy Calculations (4) Rough and Precise Grading Plans Attachment: Resolution Exhibits \[Revision 1\] (SA 16-09, V 17-03 and E 16-10) (2) Erosion Control Plans (2)Stormwater Pollution Prevention Plan (2) Geotechnical Report and Soils Report Building & Safety/Public Works General Information All structures shall be designed in accordance with the 2016CaliforniaBuilding Code, 2016 California Mechanical Code, 2016California Plumbing Code, and the 2016 California Electrical Code, 2016Residential Code and the 2016California Green Buildings Standardsadopted by the State of California. Packet Pg. 17 A.1.b Building and SafetyConditions of Approval The Developer/Owner is responsible for the coordination of the final occupancy. The Developer/Owner shall obtain clearances from each department and division prior to requesting a final building inspection from Building & Safety. Each agency shall sign the bottom of the Building& Safety Job Card. Building & Safety inspection requestscan be made twenty-four(24) hours in advance for next day inspection. Please contact (909) 825-3825. You may also request inspections at the Building & Safety public counter. All construction sites must be protected by a security fenceand screening. The fencing and screening shall be maintained at all times to protect pedestrians. Toilet facilities shall be provided for construction workers and such facilities shall be maintained in a sanitary condition. Construction toilet facilities of the non sewer type shall conform to ANSI ZA.3. Prior to building permits, applicant shall enter into a recycling agreement for construction waste according to Ordinance No. 243.A deposit will be required as part of this ordinance. Recycling receipts from the recycled company responsible for accepting the materials shall be kept in the construction office for viewing by the City Inspector.Burrtec Waste Industries has a Franchise Agreement with the City to recycle waste. Waste from the project will need to be disposed at a Burrtec Waste Industries facility. No waste shall be disposed of at any other waste facility. If waste is disposed of at an unapproved facility, funds from the deposit willbe used to offset the waste stream. Construction projects which require temporary electrical power shall obtain an Electrical Permit from Building & Safety. No temporary electrical power will be granted to a project unless one of the following items isin place and approved by Building & Safety and the Planning Department. (A)Installation of a construction trailer. or, (B)Security fenced area where the electrical power will be located. Attachment: Resolution Exhibits \[Revision 1\] (SA 16-09, V 17-03 and E 16-10) Installation of construction/sales trailers must be located on private property. No trailers can be located in the public street right of way. Building Permit Conditions 1.Prior to issuanceof Building Permits, on-site water service shall be installed and approved by the responsible agency. On site fire hydrants shall be approved by the Fire Packet Pg. 18 A.1.b Building and SafetyConditions of Approval Department. No flammable materials will be allowed on the site until the fire hydrants are established and approved. 2.Provide a geotechnical report and soils report for the grading that has been performed to establish the site lot. The City has no evidence of a grading permit obtained to establish this site. 3.Prior to issuance of permits, site grading certification and pad certifications shall be submitted to Building & Safety. Prior to concrete placement, submit a certification for the finish floor elevation and set backs of the structures. The certification needs to reflect that the structure is in conformance with the Precise Grading Plans. Compaction reports shall accompany pad certifications. 4.Prior to issuance of building permits, provide Building & Safety with a will service letter from Riverside Highland Water Company. (909) 825-4128. 5.Prior to building permit issuance, provide a clearance from the City of Colton wastewater division for the connection to City sewer system. 6.All construction projects shall comply with the National Pollutant Discharge Elimination Systems (NPDES)and the current San Bernardino County MS4 permit. 7.The structure is located in a “High Fire Zone”designation and must comply with requirements for fire resistive constructionin the Building Code as well as the San Bernardino County Fire Department regulations for high fire zone areas. 8.The structure shall be designed and built with fire sprinklers. The fire sprinkler plans shall be reviewed and approved by the fire department prior to building permits. Separate plan submittals will be necessary to San Bernardino County Fire Department. 9.The lot address of the home shall be illuminated andvisible from the street. Attachment: Resolution Exhibits \[Revision 1\] (SA 16-09, V 17-03 and E 16-10) Packet Pg. 19 A.1.b Public Works Conditions of Approval Date: October 26, 2017 Applicant:Yacoub Farsakh Address of Applicant: AKA & Assoc, 2222 Kansas Ave, Suite K Riverside, CA 92313 Site Location: APN 0276-331-49, Palm Avenue, ASA No.16-09 New Single Family Resident Provide construction plans and required documentation for review of the proposed project as follows: (1)Grant Deed showing all easements. (1) Soils Report All work performed in the public right of way shall comply with the San Bernardino County Public Works Standards or standards approved by the Public Works Director. All construction sites must be protected by a security fenceand screening. The fencing and screening shall be maintained at all times to protect pedestrians. Toilet facilities shall be provided for construction workers and such facilities shall be maintained in a sanitary condition. Special Conditions: Attachment: Resolution Exhibits \[Revision 1\] (SA 16-09, V 17-03 and E 16-10) 1.Encroachment permits are required before all work begins in the public right of way.A street cut deposit will be collected for each street cut and held for two years. 2.The applicant shall dedicate all missing right of wayif not already dedicated. All frontage improvements within R/Wshould bededicated to the Public as 30’-wide public road easement. 3.Provide any missing or damaged public improvements and they shall include, but are not limited to, pavement, curb, gutter, sidewalk and driveway approaches. Street Packet Pg. 20 A.1.b Public Works Conditions of Approval improvements will be required to extend beyond the frontage of the project to blend the streetand addressflows for drainage and traffic. 4.Minimum driveway grades shall be consistent with San Bernardino County Standard 131. Riverside County Standard 207driveway approach can be usedas an alternate. 5.Monumentation: If any activity on this project disturbsanyexistingsurvey monuments, the disturbed monumnetation shall be located andreferenced by or under the direction of a licensed land surveyor or a registered civil engineer authorized to practice land surveying prior to commencement of any activity with the potential to disturb the monumnetation, and a corner record or record of survey of the references shall be filled with the Countyof San Bernardino. 6.All existing easements must be shown onsite and/or improvement plans. 7.Public Works inspection requests can be made twenty four(24) hours in advance for next day inspection. Please contact (909) 825-3825. You may also request inspections at the Building & Safety public counter. 8.All proposed public street improvements shall be designed by persons registered and licensed pursuant to the Business and Professions Code and all street work will require a contactor licensed in the State of California and insured pursuant to the City’s insurance requirements. 9.Prior to the issuance of anencroachment permit, the applicant shall pay allDevelopment Improvement, inspection and permitfee’s to the City. Attachment: Resolution Exhibits \[Revision 1\] (SA 16-09, V 17-03 and E 16-10) Packet Pg. 21 A.1.b INTEROFFICE MEMO DATE06-06-2017 FROMJeff Stinson, County Fire Phone: (909) 387-4140 Public Safety TOHaide Aguirre,Assistant Planner SUBJECT City of Grand Terrace. PROJECT#; APN:0276-331-49; Location: Palm Ave next to Blue Mountain. Proposing to construct aR1-20-V Low Density single family residential; 2600 square foot home with 4 bedrooms and a 709 square feet 3 car garage PROJECT CONDITIONS GENERAL REQUIREMENTS/ON-GOING CONDITIONS Jurisdiction. The above referenced project is under the jurisdiction of the San Bernardino County Fire Department herein ("Fire Department"). Prior to any construction occurring on any parcel, the applicant shall contact the Fire Department for verification of current fire protection requirements. All new construction shall comply with the current Uniform Fire Code requirements and all applicable statutes, codes, ordinances and standards of the Fire Department. \[F01\] Fire Safety Area: All construction shall adhere to the applicable standards and requirements of this Fire Safety Review Area (One, Two or Three) \[FS-1/FS-2/FS-3\]overlay district, as adopted in the San Bernardino County Development Code. In Fire Hazard Areas, the applicant shall contact the San Bernardino County Building and Safety Department for a variances concerning modified one-hour fire resistive construction for the exterior wall(s). \[F48\] CONDITIONS THAT MUST BE MET PRIOR TO ISSUANCE OF BUILDING PERMITS Fire Fee. The required fire fees (currently $ 397.00) shall be paid to the San Bernardino County Fire Department/Community Safety Division (909) 386-8400. This fee is in addition to fire fees that are paid to the City ofGrand Terrace. \[F40\] Access.The development shall have a minimum of ___1_____points of vehicular access. These are forfire/emergency equipment access and for evacuation routes. Standard 902.2.1 THE FOLLOWING PRIOR TO OCCUPANCY Turnaround.An approved turnaround shall be provided at the end of each roadway one hundred Attachment: Resolution Exhibits \[Revision 1\] (SA 16-09, V 17-03 and E 16-10) and fifty (150) feet or more in length. Cul-de-sac length shall not exceed six hundred (600) feet; all roadways shall not exceed a 12 % grade and have a minimum of forty five (45) foot radius for all turns. In the FS1, FS2 or FS-3 Fire Safety Overlay District areas, there are additional requirements. Standard 902.2.1 \[F43\] Fire Sprinkler-NFPA #13D. An automatic life safety fire sprinkler system complying with NFPA Pamphlet #13D and the Fire Department standards is required. The applicant shall hire a Fire Department approved fire sprinkler contractor, or be the approved homeowner/intaller. The fire sprinkler contractor/installer shall submit three (3) sets of detailed plans (minimum 1/8" scale) with hydraulic calculations and manufacture's specification sheets to the Fire Department for approval. The required fees shall be paid at the time of plan submittal. Minimum water supply shall be in accordance with current fire department standards Packet Pg. 22 A.1.b Street Sign.This project is required to have an approved street sign (temporary or permanent). The street sign shall be installed on the nearest street corner to the project. Installation of the temporary sign shall be prior any combustible material being placed on the construction site. Prior to final inspection and occupancy of the first structure, the permanent street sign shall be installed. Standard 901.4.4 \[F72\] Residential Addressing. The street address shall be installed on the building with numbers that are a minimum of four (4) inches in height and with a one half (½) inch stroke. The address shall be visible from the street. During the hours of darkness, the numbers shall be internally and electrically illuminated with a low voltage power source. Numbers shall contrast with their background and be legible from the street. Where the building is fifty (50) feet or more from the roadway, additional contrasting four (4) inch numbers shall be displayed at the property access entrances. Standard 901.4.4 \[F81\] Attachment: Resolution Exhibits \[Revision 1\] (SA 16-09, V 17-03 and E 16-10) Packet Pg. 23 A.1.c CITY OF GRAND TERRACE NOTICE OF EXEMPTION TO: Clerk of the Board of Supervisors FROM: Planning and Development County of San Bernardino Services Department nd 385 N. Arrowhead Avenue, 2 Floor City of Grand Terrace San Bernardino, CA 92415-0130 22795 Barton Road Grand Terrace, CA 92313 Project Title: Site and Architectural Review 16-09, Variance 17-03 and Environmental 16-10 Project Location Specific: The project is located at Palm Avenue, in the County of San Bernardino, APN: 0276-331-49. Description of Project: Construct a 3,646-square foot single family residence on a 1.29-acre lot. Name of Public Agency Approving Project: Grand Terrace Planning Commission Name of Person or Agency Carrying out Project: Mr. Yacoub Farsakh Exempt Status: California Code of Regulations, Title 14, Section 15303, Infill Development Projects Reasons Why Project is Exempt: Section 15303 of the California Environmental Quality Act (CEQA) Guidelines. This section exempts the construction and location of limited number of new, small facilities or structures, such as one single-family residence, or a second dwelling unit in a residential zone. In urbanized areas, up to three single-family residences may be constructed or converted under this exemption. Lead Agency or Contact Person: Area Code/Telephone (909) 824-6621 Attachment: SA 16-09_Notice of Exemption (SA 16-09, V 17-03 and E 16-10) ______________________________ _________________ Sandra Molina Date Planning and Development Services Director C:\\users\\jlambarena\\appdata\\local\\temp\\minutetraq\\grandterracecityca@grandterracecityca.iqm2.com\\work\\attachments\\4311.doc 22795 Barton Road, Grand Terrace, California, 92313-5295 909/824-6621 Fax 909/783-2600 Packet Pg. 24