HomeMy WebLinkAboutPower Presentation CUP No 25-01City of
Grand Terrace October 16, 2025
City of Grand Terrace
Planning Commission/ Site and Architectural Review
Board Public Hearing
Presented By
Natalie Patty
Contract Planner, Planning & Development Services
Vision Statement
•Goal 3: Promote Economic
Development
•Goal 4: Develop and Implement
Successful Partnerships
•Applicant: Grand T-1, LLC
•Existing 21-acre site at 11731 Terrace Avenue
•M-2 - Industrial zoning district, with portions subject to
Agricultural and Floodplain overlays
•Existing Land Use - Trailer/Container Storage Facility
•Existing Entitlements - SA 19-03
Summary
Site Location
Project Site
Zoning and Surrounding Land Uses
•Due to condition violations, Staff directed the Planning Commission
adopted a resolution to revoke CUP 19-01 and amend SA 19-03 to update
conditions due to interdependence with CUP 19-01.
•The applicant initiated the relinquishment of CUP 19-01 and City Council
adopted a resolution approving the relinquishment and directed staff to
prepare a new CUP (CUP 25-01) and amend SA 19-03 (preserving this
entitlement ensures conditions related to site design and trail access is not
affected).
Background
Street View
Site Entry Along Western
property boundary
View Looking North
Street View
View Looking West
Looking South from Project Entry
Proposal
•A New CUP 25-01 is required for the modular office on-site.
•The existing trailer/container storage facility is a permitted use
within the M-2 Industrial zoning district.
•An amendment to SA 19-03 in requested to separate the co-mingled
conditions and ensure a more effective regulatory framework for
future use and to oversee the future development of the 4,800 SF
maintenance building.
Environmental Background
•An Initial Study was prepared in accordance with CEQA and
reviewed 21 resources including: Aesthetics, Agricultural, Air
Quality and GHGs, Biological, Cultural, Energy, Geology & Soils,
Hazards and Hazardous Materials, Hydrology & Water Quality,
Land Use & Planning, Mineral Resources, Noise, Population &
Housing, Public Services, Recreation, Transportation, Tribal
Cultural Resources, Utilities & Service Systems, Wildfire and
Mandatory Findings of Significance.
Environmental Background
•The Initial Study reviewed the development of 650 parking spaces
for semi-trailers, shipping and storage containers, and chassis.
•Other improvements reviewed in the Initial Study included:
o 900 SF modular office
o 4,800 SF maintenance building which would include regulatory
inspection, maintenance of trailers, containers, light
inspection/replacement, safety checks.
Environmental Background
•A Notice of Intent/Notice of Availability to adopt the Mitigated
Negative Declaration was distributed to agencies, interested parties,
and surrounding properties for a 20-day public review period from
December 6th through December 27, 2019.
•A total of one (1) comment was received from the City of Colton.
The comment did not identify a new environmental impact nor
increase the severity of a previously identified impact.
Environmental Background
•All potentially significant impacts identified for Biological (nesting birds), Cultural
(unknown historic and archeological resources), Geology (unknown
paleontological resources) and Tribal resources, could be reduced to less than
significant impacts with mitigation incorporated. All mitigation identified in the
Initial Study is included in the updated Conditions of Approval for SA 19-03,
Amendment No. 1
•In August 2020, City Council approved the Initial Study/Mitigated Negative
Declaration for the Project.
•In accordance with CEQA, on August 27, 2020, a Notice of Determination was filed
with the San Bernardino County Clerk of the Board.
Site Plan
M2 District Design Standards
•The Site Plan complies with the design standards set forth in Chapter 18.40,
specifically Section 18.40.050 requiring the following:
•Minimum lot area of 20,000 SF; the property is approx. 21 acres
•Minimum lot width and depth of 70 and 100 feet, respectively; (site: 1,069’ and 838’)
•Existing and proposed structures would not exceed the 35-feet;
•Front yard setback of 25 feet with 10 feet of landscape setback; site provides 50’
•Rear yard setback is met
•Lot coverage can be 100 percent within the M2 zoning district.
Modular Office
•The modular office is prefabricated and includes windows with contrasting
trim, wood-like siding panels painted grey, a low flat roof. The overall height
is 9 foot, 6 inches.
Maintenance Building
•Maintenance building would be constructed of prefabricated metal,
insulated and placed on a slab and would have a height of 20 feet.
Findings
•CUP Findings per GMC §18.83.050 can be made
Provided as Exhibit C of attachment 1
•As Conditioned, no adverse impacts would result
•Compatible with the intent of the M-2 zoning district
•Consistent with General Plan
•CEQA Exempt – §15301, Class 1, Existing Facilities
Notification
•Pursuant to the City's Municipal Code
•A mailer was sent out to all owners of real
property located within a mailing notification
radius of 500’ feet from the Project site.
•To date no responses has been received
Environmental Review
•California Environmental Quality Act
(CEQA)
•Exempt Pursuant To Section §15301, Class
1 [Existing Facilities].
Fiscal Impact
This action avoids significant costs to the City by
eliminating the need for ongoing enforcement actions,
hearings and potential legal proceedings.
Updated Exhibit
Conditions of Approval has been updated to include
general conditions, carry over conditions from SA 19-03,
and conditions to provide more detail on compliance with
the Floodplain Management Ordinance.
Staff Recommendation
Adopt the following resolutions approving:
•SA 19-03 Amendment No. 1
•CUP 25-01
•Determine that the project is exempt Pursuant to
Section 15301 Class Existing Facilities
Thank You
Questions/ Comments