HomeMy WebLinkAboutF. 12 Grand Terrace Rezoning PresentationMultifamily Rezoning to Implement
the 2021-2029 Housing Element
City Council
May 12, 2026
2
Team
Scott Hutter, Planning & Development Services Director
Gabriel Arguelles, Associate Planner
Michael Baker International
City of Grand Terrace
Hannah Kreitman, Project Manager, Housing Element Rezoning
Dan Wery, Program Advisor
Cameron Savois, Project Manager, Objective Design Standards
Nina Cai, Planning Analyst
3
Agenda
Purpose, Background, and Timeline
Proposed Rezone Standards
Revisions in Response to Community Input
Adoption and Next Steps
4
Project Purpose and Goals
Rezone 97.1 acres to the new R3-40 zone
Adopt a set of accompanying standards for the new zone
Implement 6th Cycle Housing Element Update
Prepare for upcoming 7th Cycle Housing Element
Achieve a compliant Housing Element and Comply with State Law
Use funding Opportunity from SCAG/SBCTA
5
Project Background and Timeline
March 25, 2025:
2021-2029 Housing Element Adoption
May 22, 2025:
HCD issues Letter of Conditional Compliance
December 17, 2025:
HCD Compliance and Enforcement Meeting
January 27, 2026:
Special Joint Planning Commission and City Council Session
February 5, 2026:
Community Study Session
April 2, 2026:
Planning Commission Recommends Adoption
6
Proposed
Rezone Sites
6
7
Proposed R3-40 Zone Standards
Standard
Current
R3-20/R3-24
Proposed
R3-40
Density 13 –20 du/ac /
20 –24 du/ac
20 –40 du/ac
Height 35 feet 45 feet
Front Yard Setbacks 25 feet 15 feet
Rear Yard Setbacks 20 feet 15 feet
Side Yard Setbacks 15 feet 20 feet combined
(Min 5 feet)
Setback from Single Family Zone for Portion of
Multiple Family Building over 25 Feet in Height
ODS 20 feet
8
Proposed R3-40 Zone Standards (Cont.)
Standard
Current
R3-20/R3-24
Proposed
R3-40
Private Open Space -50 sf/du for not
less than twenty-
five percent (25%)
of total units
Common Open Space -50 sf/du
9
●Reduced proposed max height from 55 feet to 45 feet
●Added Stepback requirement
●ADUs and JADUs are permitted to be added to existing legal
nonconforming uses and structures
“In no case shall a residential use that was lawfully established according
to the standards at the time of development in a residential zone be
required to be terminated or removed”
Revisions Made in Response to Community Input
10
Revisions Made in Response to Planning Commission
●Explicitly permit Duplexes, Triplexes, and Quadplexes in the
R3-40 zone
○Triplex or quadplex would meet the necessary density on
38% of the included sites
●Removed requirement for compliance with new zone in the
case of additions, damage repair, or ADUs that meet other
required provisions
11
●Present draft revisions to Planning Commission -July
●Current ongoing effort to update the Multifamily ODS
○Building Design
○Site Design
○Approval and Permitting Process
○New Graphics
●Zoning and ODS will be complementary
Objective Design Standards (ODS)
12
●Notice of Exemption Prepared
●Project statutorily exempt from CEQA pursuant to Section 21080.085
of the CEQA Statues and Guidelines
●SB 131 exempts rezones that implement the schedule of actions
contained in an approved Housing Element
California Environmental Quality Act (CEQA)
1.City Council Adoption of Zoning Code Amendment, Zone Change,
General Plan Amendment, and CEQA
2.Notify HCD of adoption
3.HCD Letter of Substantial Compliance (Certification)
Next Steps
13
THANK YOU!